BEFORE SERVICING, REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES
7
L22
-
405
TROUBLESHOOTING
ISSUE
CAUSE
STEPS TO RESOLVE ISSUE
Unit will not turn on and has no display
1. No power to the appliance
2. Power cord unplugged
3. Blown fuse(s)
1. Check circuit breaker in store to make sure it
is not tripped
2. Plug in power cord
3. Replace blown fuse(s)
Unit will not heat or controller displays
“
”
1. Float switch in the down position
2. Tripped hi
-
limit switch
3. Controller turned off
1. Check that the float switch is not stuck in
the down position and that there is sufficient
oil level in the tank.
2. Reset the hi
-
limit switch
3. Turn the controller on
Display shows
“
”
1. Filter pan not installed
2. Filter pan not installed properly
3. Door open
1. Install the filter pan and retry
2. Remove and reinstall the filter pan properly
and retry
3. Close the door and retry
Display shows
“
”
1. Oil in filter pan
2. Debris holding filter pan float up
1. Remove the oil from the filter pan and retry
2. Remove debris from the filter pan float and
retry
Display shows
“
”
1. Clogged drain
2. Drain actuator thermal limit tripped
1. Use provided clean out rod to remove clog
from drain
2. Reset thermal limit on actuator
Display shows
“
”
1. The drain tried to close and was not sensed
closed by the controller
1. Remove tools and debris from drain. The
drain will automatically attempt to close again
after 10 seconds of the error appearing.
Display shows
“
”
1. Tank is not refilling from filter pan.
1. Check that the filter motor is running.
2. Filter paper may need to be changed.
3. Strainer cap need to be cleaned.
Display shows
“
”
1. Door was opened while filtering
2. Filter pan was removed while filtering
1. Close the door and check that the filter pan
is properly installed.
2. The automatic filter process has been
canceled and the user must acknowledge the
error.
Pump wont turn on
1. Pump circuit breaker tripped or in the
“
Off
”
position.
2. Motor thermal limit tripped
3. No power to filter motor
1. Turn on the circuit breaker
2. Reset the motor thermal limit
3. Plug in unit and check store circuit breaker
for appliance. Also check power cord from
motor is secure.
Pump runs but no oil is returning to the tank
1. Filter pan not installed properly
2. Filter paper clogged with debris
3. Strainer cap clogged with debris
4. Damaged or missing strainer cap or pickup
block O
-
rings
5. Clog in pump suction or return lines
6. Pressure relief valve needs adjusting
1. Properly install filter pan
2. Change filter paper
3. Remove and clean strainer cap.
4. Replace O
-
rings
5. Remove clog
6. Adjust the pressure relief valve on the pump
head
Содержание SELVRF
Страница 20: ...BEFORE SERVICING REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES L22 405 RO 20 SCHEMATICS ...
Страница 21: ...BEFORE SERVICING REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES 21 L22 405 ...
Страница 22: ...BEFORE SERVICING REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES L22 405 RO 22 ...
Страница 23: ...BEFORE SERVICING REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES 23 L22 405 ...
Страница 24: ...BEFORE SERVICING REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES L22 405 RO 24 ...
Страница 25: ...BEFORE SERVICING REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES 25 L22 405 NOTES ...