If the probe is suspect, check its resistance and the oil/air
temperature at which it was taken. Compare these values
on the chart below.
If the probe returns an open circuit or 0 Ohms reading it
should be replaced. If the resistance varies more than 30
Ohms when being checked between 325-375°F the probe
will give a false temperature reading on the computer and
should be calibrated (up to 10°F) or replaced. However,
it will continue to operate at a slightly higher or lower tem-
perature.

Allow the oil to cool and check the probe resistance at a
lower temperature. As can be seen from the chart a greater
variation can be tolerated at a lower temperature.

Heat Demand Contactor:

The heat demand contactor has a 24VAC coil and will
energize when the correct voltage is supplied to the coil.
When energized, the contacts will close, allowing current
to flow through the elements. The coil resistance is 192
ohms out of circuit.

Hi Limit:

The  hi - limit switch is a normally closed switch until the
temperature at the hi-limit bulb reaches 425°F ± 20°F.

WARNING!

This test should be performed by a qualified
technician only! Monitor the fryer closely. This
test will cause the oil to heat past the normal
operating temperature and can cause damage to
the machine and its operator if care is not taken.

WARNING!
This test will cause the elements to heat
continuously. Remove test resistor when test is
complete. Leaving the test resistor in the fryer
could cause damage to equipment and/or personal
injury.

To test the hi-limit, use a 2k

 - 5k

 resistor to simulate

a 230°F - 275°F temperature. This will cause the
elements to heat continuously until the hi-limit trips or the
fryer is turned off.

•If the fryer is equipped with a 

computer or digital

controller

, plug the resistor in at connector J41

behind the front panel.

•If the fryer is equipped with a 

solid state

controller 

behind the door, plug the resistor in at

connector J43 behind the front panel.

If the switch does not trip between the prescribed
limits it is defective and should be replaced. Once
tripped, the switch cannot be reset until the oil has
cooled to approximately 375°F + 20°F. If the
switch does not reset after oil has cooled it is
defective.
Once the oil has cooled the hi-limit reset button
must be pressed to reset the hi-limit relay on CE
and export units only.

Drain Valve & Return Valve Switches:

These switches are a magnetically operated
proximity switches. When the Drain Valve handle is
moved to the open position, the Actuator will move
away from the switch causing the switch to open.
When the Drain Valve is closed the switch will
close.

Opening the RED return valve handle will close the
proximity switch causing the "pump on" relay to be
energized. The pump will begin to pump. Closing
the return valve handle will de-energize the relay
and the pump will stop pumping. These switches
can also be checked with an Ohm meter. The
normal gap between the Actuator and the Sensor
switch on the valve handle is 

1

/

8

" - 

1

/

4

" (3 - 6mm).

Transformer:

Transformers are multiple input voltage 24 volt output
voltage and can be checked by reading the input and
output voltages. A quick check for 24VAC can be
done at the relay board behind the computer. The
AC led will be lit if the F1 fuse is good and the board
is receiving 24VAC

Elements:

Each Element has three coils inside it, check all element

Содержание SEH50

Страница 1: ...and Exploded Parts For Electric Fryers Covering Models SEH50 Full and Split Pitco Frialator Inc P O Box501 JctI 89 I 93Concord NH03302 0501 509Route3A Bow NH03304 800 258 3708 603 225 6684 FAX 603 225 8497 www pitco com FRANCAIS US CAN GB ...

Страница 2: ...RVICE TECHNICIAN THE MODEL SERIAL NUMBER AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA PLATE LOCATED ON THE INSIDE PANEL OF THE DOOR NOTICE THISAPPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY ANDAS SUCH SHOULD BE OPERATED BY FULLY TRAINED PERSONNEL NOTICE IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BYAQUALIFIED TECHNICIAN ONAYEARLY BASIS WARNING THE POWER SUPPLY MUST BE DISCONNECTED SERVI...

Страница 3: ...Chart 4 Basic Trouble Shooting 6 Relay Board Component Explanation 8 Reserved for Ladder Diagram 11 Reserved for Schematics 12 25 Basic Parts List 27 Exploded Drawings 28 37 Element and Tank Components 28 Pump Box and Drain Manifold 30 Main Entrance Box 32 Pump Assembly and Filter Pan 34 Wire Harness 36 US CAN GB ...

Страница 4: ...F 20 F the computer will have to be turned off and back on for the unit to heat Filter System Opening the RED return valve handle will close the proximityswitchcausingthe pumprun relayto beenergized Thepumpmotorwillbegintorun Closingthereturnvalvehandlewillde energizethe relayandthepumpmotorwillstoprunning Thepumpsystemisequippedwithacircuitbreaker whichwillde energizethesystemandtheheattape in th...

Страница 5: ...istor to simulate a 230 F 275 F temperature This will cause the elementstoheatcontinuouslyuntilthehi limittripsorthe fryeristurnedoff If the fryer is equipped with a computer or digital controller plug the resistor in at connector J41 behindthefrontpanel If the fryer is equipped with a solid state controllerbehind the door plug the resistor in at connector J43 behind the front panel If the switch ...

Страница 6: ...n 8 heat demand and a 24VAC input at pin 6 heat feed back If the controller does not receive the 24VAC input at pin 6 in approximately 90 seconds the controllerwilldisplay HEATFAIL or IGNITIONFAIL URE This would indicate a break in the heat demand or heat feed back circuit 1 Check the hi limit switch is it open or tripped 2 Check the ignition module sensing pilot flame locked out 24VAC at MVtermin...

Страница 7: ...d the controller Ifnoneoftheindicatorsilluminatewhenthecontrolleris turnedon verifythatthedrainvalveisclosedandthatthe magnetic proximity switch has continuity when the drain valve is closed Also verify that there is 24VAC at pin 1 24 VAC supply and pin 5 24VAC input from DVI Backup Solid State Control The backup solid state control works the same as the pri marysolidstatecontrol withtheexceptiono...

Страница 8: ...efective D Check input power Repair or call a qualified electrician Oil is hotter or colder than computer controller displays A Temperature calibration B Probe C Probe wiring terminals A Adjust temperature offset up to 10 F B Check replace if defective C Clean or repair terminals Computer displays DRAINING or TURN OFF A Blue drain valve not fully closed B Sensor switch C Incorrect switch gap align...

Страница 9: ...Sensor switch C Incorrect switch gap alignment A Check position of handle B Switch may be loose or have loose wires replace if defective C Check gap alignment replace if defective Oil is returning to the vat slowly or not at all A Dirty filter paper B Strainer cap dirty C Filter pan not pushed in completely D O rings not sealing on pick up tube A Change filter paper B Remove strainer cap and clean...

Страница 10: ...nput voltage from transformer Relay Board Note Note If the fryer is equipped with a computer or solid state digital at connection J33 there will be a jumper from pin 2 to pin 10 to supply 24 VAC to pin 2 at connection J31 to supply the controller with 24VAC J connectors are marked on the relay board With 24 VAC supplied to pin 2 at connector J35 and a good F1 fuse the relay board will have a 24 VA...

Страница 11: ...ND ENABLE HEAT DEMAND TO DRAIN OR FLOAT SWITCH 24VACH 1 3 NONE BASKET LIFT R BASKET LIFT L SIDE ON DC HEAT DEMAND 24VDC RETURN 24VAC RETURN HEAT FEEDBACK 6 2 4 5 7 8 10 9 TEMPERATURE TO PRIMARY COOKING CONTROLLER FUSE SIDE ON K3 K1 HEAT DEMAND HEAT FEED BACK 24VACH POWER 24VACN RETURN DRAIN OR FLOAT SWITCH 24VAC POWER SWITCHED HEAT DEMAND NONE NONE SIDE ON DC RETURN NONE NONE 7 DC COMMON BASKET LI...

Страница 12: ...10 L22 238 Rev 1 08 03 Schematics ...

Страница 13: ...DBACK INPUT 24 VAC INPUT 24 VAC COMMON 24 VAC RELAY BOARD SIDE ON HEAT DEMAND HEAT DEMAND CONTACTOR SIDE ON CONTACTOR F1 FUSE TRANSFORMER AC SO HD 24 VAC COMMON HI LIMIT SWITCH DOMESTIC ONLY DRAIN SWITCH NO NC NO NC HI LIMIT RESET 24 VAC COMMON 24 VAC TO TRANSFORMER TO HI LIMIT SWITCH CONNECTOR CE EXPORT ONLY ...

Страница 14: ...12 L22 238 Rev 1 08 03 ...

Страница 15: ...13 L22 238 Rev 1 08 03 ...

Страница 16: ...14 L22 238 Rev 1 08 03 ...

Страница 17: ...15 L22 238 Rev 1 08 03 ...

Страница 18: ...16 L22 238 Rev 1 08 03 ...

Страница 19: ...17 L22 238 Rev 1 08 03 ...

Страница 20: ...18 L22 238 Rev 1 08 03 ...

Страница 21: ...19 L22 238 Rev 1 08 03 ...

Страница 22: ...20 L22 238 Rev 1 08 03 ...

Страница 23: ...21 L22 238 Rev 1 08 03 ...

Страница 24: ...22 L22 238 Rev 1 08 03 ...

Страница 25: ...23 L22 238 Rev 1 08 03 ...

Страница 26: ...24 L22 238 Rev 1 08 03 ...

Страница 27: ...25 L22 238 Rev 1 08 03 ...

Страница 28: ...26 L22 238 Rev 0 08 03 Exploded Drawings and Parts Lists ...

Страница 29: ...aker 208 240V 60130301 120 24V Transformer 60130302 230 240 24V Transformer 60130303 208 24V Transformer PP11058 24VAC SPST Relay 120V 60104701 24VAC DPDT Relay 208 240V 60132701 0 2A Time Delay Fuse 60133503 120V Heat Tape Pump 60133504 230 240V Heat Tape Pump 60133501 120V Heat Tape Flush Hose 60133502 230 240V Heat Tape Flush Hose PP11104 1 Viton O ring 60138701 Full LH Non Locking Drain Valve ...

Страница 30: ... Element 230V 50006612 Element 240V 50006613 Element 480V 4 60088003 Bolt Element 1 4 x20x3 4 SS 5 60141201 Hi Limit Switch 6 A3342902 Lower Hi Limit Bracket 7 PP11366 Screw 10 24 X 5 8 PHH SS TF 8 A3342802 Upper Hi Limit Bracket 9 PP10665 Screw 10 24 X 3 8 10 B6700605 C Temperature Probe 11 A3342504 Rear Probe Bracket 12 A4108302 Splash Back 13 A3342502 Front Probe Bracket 14 60138101 Basket Hang...

Страница 31: ...29 L22 238 Rev 0 08 03 Figure 1 ...

Страница 32: ...Non locking Handle 60138703 Drain Valve Full Right Split W Locking Handle 6 A7021701 Drain Valve Nipple 7 A7022201 Drain Flange 8 A7022101 Drain Ferrule 9 B6665101 Drain Elbow 10 60088002 Hex Bolt 3 8 x16x1 1 4 11 P0082700 Lock Washer 3 8 12 60127701 Drain Line Clamp 13 60059302 Drain Line Gasket 14 B6664701 Drain Down Spout Full Full B6673301 Drain Down Spout Split 15 60138702 Drain Valve Left Sp...

Страница 33: ...31 L22 238 Rev 0 08 03 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Pump Entrance Box viewed from bottom Figure 2 ...

Страница 34: ...60127301 Relay Board 60132901 Relay Board Insulation 3 P5047301 3 Post Terminal Block 4 60139201 Heat Demand Contactor 5 PP10560 Side On Contactor 6 PP10429 Transformer 120 208 240VAC 7 60140701 Rcpt 10A 250V IE320F Screw In 8 P5045282 4 Post Terminal Block 9 B5305001 DVI Return Switch PP10263 DVI Return Actuator not shown ...

Страница 35: ...33 L22 238 Rev 0 08 03 1 2 3 4 5 6 7 8 9 4 2 4 5 6 3 Figure 3 ...

Страница 36: ...VAC Motor Only PP10417 5 GPM Pump Only 11 P6071516 3 4 x 4 NPT Nipple 12 PP11104 1 x 1 18 viton O ring 3 required 13 A7027602 Pickup Tube Receiving Block 14 P7036603 3 4 NPT Coupling 15 60132201 Hose Teflon Swivel FxMPT 16 60128008 Tbg Flex Return Line 0 5 x 15 5 60128009 Tbg Flex Return Line 0 5 x 19 60128010 Tbg Flex Return Line 0 5 x 22 60128011 Tbg Flex Return Line 0 5 x 10 17 60131801 Return ...

Страница 37: ...35 L22 238 Rev 0 08 03 20 21 22 23 1 1 2 3 4 6 7 8 9 10 11 12 5 13 14 15 16 17 18 19 Figure 4 ...

Страница 38: ...753701 WRG HV DELTA SGL SEH50 B6754001 WRG HV WYE DUAL SEH50 HIGH VOLTAGE HARNESSES NOT SHOWN B6752401 WRG CNTRL LFT SNGL SEH50 B6752501 WRG CNTRL RIGHT SEH50 NOT SHOWN 2X 3 0 COIL 4 5 L1 A1 A2 10 0 K10L COIL A B P35 P34 P32 J 4 3 J41 5 0 2 5 7 B 6 4 0 A 1 T1 BS1 K10L GND STRIP J 8 J 5 J7 J 4 J2 P2 2 8 4 3 5 0 4 0 2 5 9 0 24VAC 2 5 5 5 12 0 2 5 5 5 L3 3 4 2 5 2 1 10 6 2X 2X 3 0 9 5 1 10 1 B 0 5 6 ...

Страница 39: ... BK 10 11 J 1 2 3 4 5 6 7 8 9 12 9 12 8 7 6 5 2 3 4 1 11 10 1 25 1 25 60 00 J1 J2 SCHEMATIC Y BK GR W BK BK R P3 BL BK BK 10 11 P2 1 2 3 4 5 6 7 8 9 12 9 12 8 7 6 5 2 3 4 1 11 10 1 25 228 00 P2 P3 4 50 50 TO REAR OF FRYER TO HOOD MOUNTED CONTROLLER 50 B6749401 CABLE EXTERNAL REMOTE B6749301 CABLE INTERNAL REMOTE GND N L GND N L 60128501 CORD FEMALE IEC NEMA 5 15 Figure 6 ...

Страница 40: ...tern Standard Time Monday through Friday toll free at 800 258 3708 US and Canada only or 603 225 6680 In the event of problems with or questions about your order please contact the Pitco Frialator Autho rized Service and Parts representative ASAP covering your area through Pitco at 800 258 3708 US only 24 hours L22 238Rev0 08 03 ...

Отзывы: