background image

Instrukcja

 

monta

ż

u

 

i

 

obs

ł

ugi

 

suszarek

 

do

 

r

ą

k

XT 1000 E

XT 1000 EC

XT 1000 ES

9–12

21–

25–28

L

 

  Dieses Gerät nicht ohne Beachtung der Gebrauchsanleitung verwenden.

47–50

Mounting Instructions and

Directions for Use

 

https://wszystkodobasenow.pl/suszarka-do-rak-basenowa-starmix-xt1000

Содержание XT 1000 E

Страница 1: ...do rąk XT 1000 E XT 1000 EC XT 1000 ES 9 12 21 25 28 L Dieses Gerät nicht ohne Beachtung der Gebrauchsanleitung verwenden 47 50 Mounting Instructions and Directions for Use https wszystkodobasenow pl suszarka do rak basenowa starmix xt1000 ...

Страница 2: ...the following relevant regulations EN 55014 1 2006 EN 6100 3 2 2006 EN 61000 3 3 2008 EN 55014 2 1997 A2 2008 EN 61000 4 2 1995 A2 2001 EN 61000 4 3 2006 A1 2008 EN 61000 4 4 2004 EN 61000 4 5 2006 EN 61000 4 6 2007 EN 61000 4 11 2004 IPX1 0 We declare with exclusive responsibility that this product complies with the EU Directive and the relevant standardst 0 English ...

Страница 3: ...Safety advice Danger of suffocation Keep packaging material such as plastic bags away from children In case of any leakage of foam or liquid immediately switch off the dryer Do not start the dryer device including its accessories if the dryer device shows detectable damage fissures cracks the power connection line is defective or shows fissuring or ageing or any invisible defect is suspected after...

Страница 4: ...GB 3 Minimum distances 0 6m 0 6m R0 6m 0 6m 0 6m R0 6m R1 2m 4 Wiring diagrams Elektronikplatine Motor mit Thermostat Thermostat braun Lüsterklemme blau grün gelb Heizung mit Temperatursicherung Transistor ...

Страница 5: ...Hz Rated power Watt 900 900 900 Max power Watt 1000 1000 1000 Motor output Watt max 500 max 500 max 500 Heating output Watt max 500 max 500 max 500 Air flow l sec 28 28 28 Speed of air flow m sec 90 90 90 Hand drying time sec ca 15 ca 15 ca 15 Weight kg 3 8 3 8 3 8 Dimensions W x D x H mm 250 x 138 x 180 250 x 138 x 180 250 x 138 x 180 ...

Страница 6: ...afety regu lations In rooms with showers and bath tubs the appliance must be installed with the minimum distances laid down in the VDE regulations 0 6 mtrs 24 inches from the edge of the shower and or bath and 1 2 mtrs 48 inches from a shower head Carrying out any work or cleaning the appliance make sure that it is isolated from the power supply 1 3 5 4 2 ...

Страница 7: ...hapter entitled Safety instructions THIS MAY ONLY BE CARRIED OUT BYAQUALIFIED ELECTRICIAN Place the cover on the appliance again and fix it with the two anti theft screws Tighten the screws by hand 7 Cleaning and servicing Clean the air inlet openings to remove sticking fluff and dust as required with a narrow vacuum cleaner fitting Remove any dirt which is still stuck in the air inlet with a stif...

Страница 8: ...34 16 Explosionszeichnung ...

Отзывы: