                                                                                               11                                                        L80-029 Rev 5  10/07

appliance is in operation, or can be detected visually by watching the burner flame through the air collars. The
sound of the burners will be inconsistent and the flame may appear to ‘peel’ off of the burner face.
A certain amount of flame roll out during ignition is normal. However, excessive flame roll out during burner
operation is abnormal. Excessive flame roll out will cause undue heating in the burner area and will cause the
thermal cut out switch to trip. If there is significant flame roll out upon ignition or during normal operation, the
flue baffle setting may be too restrictive and will need to be adjusted to a more open position.

Determine whether or not the appliance you have upgraded has flue baffles. After performing this upgrade
procedure, observe the appliance during startup and normal operation. If pulsing burners or extreme flame roll
out are detected, adjust the flue baffle according to the following
procedure.

Follow this procedure to verify proper setting of flue baffles
and adjust if necessary:

a.  Ensure that the appliance is installed properly under the

hood in the manner in which it is intended to be used.
Turn the appliance on and allow it to execute the
cleaning cycle and go into normal operation. Observe
the operation of the main burners as the appliance
brings the oil to set point, during idling and during
cooking operations.

b.  If the burners appear to pulse or the flame is lifting off of

the burner face proceed to step c of this section of these
instructions. If there appears to be significant roll out
during ignition or any time during operation, proceed to
step d of this section of these instructions.

c. 

For pulsing/lifting burner flame

: Turn the appliance

off and allow it to cool. Pull the appliance out from under
the hood and loosen the screws securing the adjustable
slide plate on the flue baffle. Move the slide plate toward
the rear of the appliance to a more restrictive position
and retighten the screws. Repeat steps a and c until no
pulsing or flame lift is observed.

d. 

For excessive flame roll out

: Turn the appliance off and allow it to cool. Pull the appliance out

from under the hood and loosen the screws securing the adjustable slide plate on the flue baffle.
Move the slide plate toward the front of the appliance to a less restrictive position and retighten the
screws. Repeat steps a and d until flame roll out is minimized.

e.  Observe burner operation while allowing the appliance to heat up and during hot operation

(cooking and idling): the flue baffle must be adjusted correctly to allow the appliance to operate
properly during both (cold) start up and normal (hot) use conditions. It may be necessary to fine
tune the flue baffle setting for proper operation under both conditions.

WARNING

If the flue baffle CANNOT be adjusted properly, the facility must have the

ventilation system checked immediately to be sure that it is operating within

normal specifications. After the ventilation system is corrected, the baffle

setting must be rechecked. Failure to correct ventilation problems or

properly set flue baffles will result in extremely poor appliance operation

and possible equipment damage.

LESS RESTRICTIVE 

 

MORE RESTRICTIVE 

Содержание L80-029

Страница 1: ...on and retain these instructions for the life of the equipment Model __________________________ Serial __________________________ Date Upgraded ___________________ Technician _________________________ Installation Instructions for the PITCO Self Cleaning Burner System E N G L I S H ...

Страница 2: ...kit should only be performed by a competent service technician WARNING Do not attempt to move a cooking appliance when the unit is at operating temperature Serious personal injury could result if skin comes in contact with the hot surfaces WARNING DO NOT sit or stand on this appliance Serious injury could result from falling or contact with hot shortening oil WARNING Improper installation alterati...

Страница 3: ... face by incinerating any foreign matter that has accumulated from the previous day s operation The Pitco Self Cleaning Burner System is designed to help maintain proper operation and efficiency of your appliance s combustion system by minimizing the build up of any foreign material inside the burner housings Proper installation of this upgrade and periodic maintenance of the appliance are critica...

Страница 4: ...onnect the control harness and tuck it out of the way to avoid damaging the harness during this procedure Be sure to store the control in a safe place to avoid accidental damage to it c Using a 7 16 wrench remove the pilot tubing from the gas valve by turning the brass fitting counter clockwise There is no need to remove the pilot from the burner assembly WARNING Ensure that the tank contents have...

Страница 5: ...r head WARNING Be sure to keep the removed burners separate from burners supplied with the upgrade kit The existing burners WILL NOT work with the Pitco Self Cleaning Burner System DO NOT attempt to use the old burners with the Pitco Self Cleaning Burner System an unsafe condition may occur g Replace the burners to the LEFT of the pilot with burners supplied with the Pitco Self Cleaning Burner Sys...

Страница 6: ...re installed correctly Improperly mounted or poorly aligned burners may result in an unsafe condition or poor appliance performance They should be mounted properly on the orifice fittings facing straight into the burner tubes and secured tightly to the appliance Follow this procedure for installation of the SCBS Valve NOTE The valve type you receive in your kit may differ in appearance slightly fr...

Страница 7: ...ng to ensure a gas tight seal NOTE The threads on this fitting 1 8 NPT and compression are not interchangeable Be sure to install the NPT side of this fitting into the gas valve Failure to complete this step correctly could damage the threads of both the fitting and the pressure test port and may result in gas leakage at this joint c Remove the 1 8 NPT X 90 compression fitting from the other end o...

Страница 8: ... Reinstall the pilot tubing into the gas valve h Reconnect the control harness to the main gas valve and if you removed a Solid State Control earlier in this procedure you may re install it at this time Follow this procedure to prepare and install the SCBS Control Board and Harnesses a Using a phillips head screwdriver remove the two screws that secure front panel and rotate the control assembly d...

Страница 9: ...ined into one single harness NOTE It is critical for proper operation that the insulation paper is installed Failure to install the insulation paper may cause soldered joints on the back of the Control board to short out and damage the Control board and or appliance d Plug four pin connector on SCBS Harness into SCBS Relay Board and ground as shown using the existing fastener to secure ground cabl...

Страница 10: ...ws holding the cable retainer plate onto the appliance and remove the cable retainer plate leaving the control cable held in place by the square strain relief Replace the cable retainer plate that you removed with the new one provided in the kit Cable retainer plate style varies from model to model the one that came with your kit should look exactly like the one that you removed with an added hole...

Страница 11: ...nt of the appliance Mount the assembly by straddling it on the two burners on either side of the pilot and positioned up to where the flange on the assembly meets with the bottom of the flange on the burner web see photos at right l Fasten the Thermal Limit Switch to the flange on the burner web using two self drilling fasteners provided in the Pitco Self Cleaning Burner System Kit Connect the lea...

Страница 12: ... at the main burner orifice of each burner Interwaiting period 2 8 seconds The Main and SCBS valves de energize for this period The pilot remains lit Normal operation resumes N A The appliance operates normally and begins to heat up The SCBS Valve remains de energized until power to the appliance is recycled There is no flame on the SCBS Arm There is no burn at the main burner orifices With the Pi...

Страница 13: ... these instructions If there appears to be significant roll out during ignition or any time during operation proceed to step d of this section of these instructions c For pulsing lifting burner flame Turn the appliance off and allow it to cool Pull the appliance out from under the hood and loosen the screws securing the adjustable slide plate on the flue baffle Move the slide plate toward the rear...

Страница 14: ...ation Refer to flue baffle adjustment procedure in these instructions to set flue baffle to a less restrictive setting Model MG2 or MG2T flue baffle is set too restrictively Faulty hi limit switch Appliance will not maintain temperature properly Refer to Service and Parts manual to diagnose this problem and replace temperature probe Refer to Service and Parts manual to diagnose this problem and re...

Страница 15: ...13 L80 029 Rev 5 10 07 ...

Страница 16: ...L80 029 Rev 5 10 07 14 ...

Страница 17: ...15 L80 029 Rev 5 10 07 ...

Страница 18: ...L80 029 Rev 5 10 07 16 ...

Страница 19: ...17 L80 029 Rev 5 10 07 ...

Страница 20: ...L80 029 Rev 5 10 07 18 ...

Страница 21: ...19 L80 029 Rev 5 10 07 ...

Страница 22: ...L80 029 Rev 5 10 07 20 ...

Страница 23: ... the installation of the SCBS upgrade Wire harnesses and pilot tubing are omitted to provide better clarity In order to give the installer a sense of part orientation and location the gas piping parts valve tubing runner arm and fittings of the SCBS system are shaded For clarity the thermal limit switch assembly is not shaded ...

Страница 24: ... about your order please contact the Pitco Frialator factory at 800 258 3708 US and Canada only or 603 225 6684 World Wide In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the numbers listed to the left ...

Отзывы: