background image

                                                                                                                                                      L20-299   Rev. 0   6/06

 

Pitco Frialator

 PO Box 501 Concord, NH  03302-0501     603-225-6684

IMPORTANT FOR FUTURE REFERENCE

Please complete this information and retain this
manual for the life of the equipment:

Model #: ________________________

Serial #: ________________________
Date Purchased: __________________

Installation and Operation Manual

Covering

Model 65 Series Fryer

with Millivolt Gas Valve

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE

ENGLISH

Содержание L20-299

Страница 1: ...mplete this information and retain this manual for the life of the equipment Model ________________________ Serial ________________________ Date Purchased __________________ Installation and Operation...

Страница 2: ...appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device This quick disconnect must comply with ANSI Z24 41 To limit the movement of t...

Страница 3: ...Systems 4 Lighting Instructions 5 Pilot Flame Adjustment 5 Main Burner System Adjustment 6 Initial Cleaning 7 OPERATION 8 Filling the Tank 8 Filling the tank with liquid shortening oil 8 Filling the t...

Страница 4: ...This appliance must be installed with legs or casters it cannot be curb mounted Curb mounting will seriously inhibit this appliances ability to effect proper combustion WARNING This appliance must be...

Страница 5: ...essary for servicing and proper burner operation Ensure that you meet the minimum clearance requirements specified in this manual Installation Clearances The clearances shown below are for combustible...

Страница 6: ...from the fuel line If the fuel line is to be tested at a pressure equal to or less than PSIG 3 45 kPa the appliance can be connected during the test but the unit s gas valve must be shut Test all gas...

Страница 7: ...sulting increased flow of air through the combustion system will cause improper operation poor temperature recovery poor ignition and could extinguish the pilot Initial Adjustments After your applianc...

Страница 8: ...fer to the operator troubleshooting section of this manual e Once a pilot flame has been established turn the gas valve knob counterclockwise to the ON position f Set the thermostat control knob to th...

Страница 9: ...re tap plug and connect an accurate pressure gauge range of 0 16 w c in 0 1 increments or manometer b Turn on this and all appliances connected to the gas supply line and light their main burners The...

Страница 10: ...er let the water level go below the OIL LEVEL mark stamped on the tank c Using the cleaning brush scrub the inside of the tank to remove the protective coating d When cleaning is complete turn the app...

Страница 11: ...the rack covering the tubes tube rack b Cut the solid shortening oil into cubes no larger than one inch ALWAYS pack the shortening oil below between and on top of the burner tubes DO NOT leave any lar...

Страница 12: ...bility of the appliances main burners to operate Complete shutdown turns off the gas supply to the appliance STANDBY Turn the thermostat to the OFF position Turn the gas valve knob clockwise to the PI...

Страница 13: ...boiling If you have water in the tank you will need to drain it dry it and fill it with shortening oil Follow the filling instructions in this manual To check the calibration of your appliance refer t...

Страница 14: ...e Turn the adjustment screw until the burners come on at 325 F 163 F f Replace the knob and allow the appliance to cycle 4 to 6 times Check the temperature of the digital thermometer against the therm...

Страница 15: ...foaming and boil over c Allow the appliance to soak for 20 minutes to soften shortening oil deposits Use the cleaning brush to scrub and remove any residue from the tank tubes and side walls d When f...

Страница 16: ...TROUBLESHOOTING Basic Troubleshooting Flow Chart Refer to this section to correct common problems that may be encountered during the course of normal operation If applicable a schematic is provided o...

Страница 17: ...WIRING DIAGRAM 14 WIRING DIAGRAM...

Страница 18: ...15 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 19: ...16 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 20: ...Installation and Operation Manual Covering Model 65 Series Fryer with Millivolt Gas Valve THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE L20 299 Rev 0 06 06...

Отзывы: