background image

                                                                                                                                                      L20-299   Rev. 0   6/06

TO THE PURCHASER

Post in a prominent location the instructions
to be followed in the event that an operator
smells gas. Obtain this information from
your local gas supplier.

WARNING

There is an open flame inside this appliance.
The unit may get hot enough to set nearby
materials on fire. Keep the area around the
appliance free from combustibles.

WARNING

DO NOT

 supply the appliance with a gas

that is not indicated on the data plate. If you
need to convert the appliance to another
type of fuel, contact your dealer.

WARNING

DO NOT 

use an open flame to check for

gas leaks!

WARNING

If gas flow to appliance is interrupted, or pilots
extinguish, wait 5 minutes before attempting to
relight the pilot to allow any residual gas in
appliance to dissipate.

WARNING

Ensure that the appliance can get enough air to
keep the flame burning correctly. If the flame is
starved for air, it can give off a dangerous carbon
monoxide gas. Carbon monoxide is a clear
odorless gas that can cause suffocation.

WARNING

Adequate means must be provided to limit the
movement of this appliance without depending on
the gas line connection. Single appliances
equipped with legs must be stabilized by installing
anchor straps. All appliances equipped with
casters must be stabilized by installing restraining
chains. If a flexible gas line is used, an additional
restraining cable must be connected at all times
when the appliance is in use.

WARNING

An appliance equipped with casters and a flexible
gas line must be connected to the gas supply with
a quick disconnect device. This quick disconnect
must comply with ANSI Z24.41. To limit the
movement of the appliance without depending on
the connector or quick disconnect, a restraining
cable must also be installed.

WARNING

Models with electric controls are equipped with a
shortening/oil proof electrical supply cord, with a
three prong safety plug. This is to protect
operators from electrical shock hazard in the event
of an equipment malfunction. DO NOT cut or
remove the grounding (third) prong from this plug.

WARNING

This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the 

National Electrical

Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.2, 

as applicable.

WARNING

The power supply must be disconnected before
servicing or cleaning this appliance.

WARNING

Do not attempt to move this appliance when the
unit is at operating temperature or filled with hot
shortening/oil. Serious personal injury could result
if skin comes in contact with the hot surfaces or
shortening/oil.

WARNING

DO NOT sit or stand on this appliance. Serious
injury could result from falling or contact with hot
shortening/oil.

FOR YOUR SAFETY

DO NOT store or use gasoline or other flammable vapors or liquids in the
vicinity of this or any other appliance.

WARNING

Improper installation, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.

Содержание L20-299

Страница 1: ...mplete this information and retain this manual for the life of the equipment Model ________________________ Serial ________________________ Date Purchased __________________ Installation and Operation...

Страница 2: ...appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device This quick disconnect must comply with ANSI Z24 41 To limit the movement of t...

Страница 3: ...Systems 4 Lighting Instructions 5 Pilot Flame Adjustment 5 Main Burner System Adjustment 6 Initial Cleaning 7 OPERATION 8 Filling the Tank 8 Filling the tank with liquid shortening oil 8 Filling the t...

Страница 4: ...This appliance must be installed with legs or casters it cannot be curb mounted Curb mounting will seriously inhibit this appliances ability to effect proper combustion WARNING This appliance must be...

Страница 5: ...essary for servicing and proper burner operation Ensure that you meet the minimum clearance requirements specified in this manual Installation Clearances The clearances shown below are for combustible...

Страница 6: ...from the fuel line If the fuel line is to be tested at a pressure equal to or less than PSIG 3 45 kPa the appliance can be connected during the test but the unit s gas valve must be shut Test all gas...

Страница 7: ...sulting increased flow of air through the combustion system will cause improper operation poor temperature recovery poor ignition and could extinguish the pilot Initial Adjustments After your applianc...

Страница 8: ...fer to the operator troubleshooting section of this manual e Once a pilot flame has been established turn the gas valve knob counterclockwise to the ON position f Set the thermostat control knob to th...

Страница 9: ...re tap plug and connect an accurate pressure gauge range of 0 16 w c in 0 1 increments or manometer b Turn on this and all appliances connected to the gas supply line and light their main burners The...

Страница 10: ...er let the water level go below the OIL LEVEL mark stamped on the tank c Using the cleaning brush scrub the inside of the tank to remove the protective coating d When cleaning is complete turn the app...

Страница 11: ...the rack covering the tubes tube rack b Cut the solid shortening oil into cubes no larger than one inch ALWAYS pack the shortening oil below between and on top of the burner tubes DO NOT leave any lar...

Страница 12: ...bility of the appliances main burners to operate Complete shutdown turns off the gas supply to the appliance STANDBY Turn the thermostat to the OFF position Turn the gas valve knob clockwise to the PI...

Страница 13: ...boiling If you have water in the tank you will need to drain it dry it and fill it with shortening oil Follow the filling instructions in this manual To check the calibration of your appliance refer t...

Страница 14: ...e Turn the adjustment screw until the burners come on at 325 F 163 F f Replace the knob and allow the appliance to cycle 4 to 6 times Check the temperature of the digital thermometer against the therm...

Страница 15: ...foaming and boil over c Allow the appliance to soak for 20 minutes to soften shortening oil deposits Use the cleaning brush to scrub and remove any residue from the tank tubes and side walls d When f...

Страница 16: ...TROUBLESHOOTING Basic Troubleshooting Flow Chart Refer to this section to correct common problems that may be encountered during the course of normal operation If applicable a schematic is provided o...

Страница 17: ...WIRING DIAGRAM 14 WIRING DIAGRAM...

Страница 18: ...15 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 19: ...16 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 20: ...Installation and Operation Manual Covering Model 65 Series Fryer with Millivolt Gas Valve THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE L20 299 Rev 0 06 06...