PITCO Frialator, Inc.
P.O. Box 501, Concord, New Hampshire 03301
9
9
10
10
1
1
4
4
5
5
6
6
1
1
2
2
1
1
Fryer temperature recovery
too slow.
1
Replace thermopile or
thermocouple
Defective thermopile or
thermocouple
Reset
SECTION 2S TROUBLESHOOTING CHART (Cont'd)
Turn handle counter clockwise
as far as it will go.
Unitrol valve handle not turned
to ON.
Defective probe.
Defective thermopile or
thermocouple
Replace magnet
Clean.
Minimum operating pressure:
Natural Gas- 4.0" w.c.;
Propane Gas- 10.0" w.c.
1
Replace baffles.
TROUBLE
POSSIBLE CAUSE
REMEDY
Low gas pressure.
Pilot flame lit but burners will
not light.
Pilot flame and main
burners cut off while
cooking.
2
2
Pilot will light but Unitrol pilot
gas valve will not hold open
automatically.
Float switch bulb off or stuck
down.
Install float switch bulb and new
clip.
Check electric supply circuit
2
2
3
3
Supply cord may not be
plugged in or switch may not be
turned on.
5
5
Replace probe.
Defective computer.
Replace Computer.
Defective Unitrol.
Replace Unitrol.
Dirty burners.
Hi-Limit tripped
Baffles in heat tubes may be
burned out.
3
3
4
Call factory to learn proper
sizes.
Incorrect burner orifices.
Carbon build-up on heat tubes.
Clean fry tank and tubes.
4
Pilot flame is yellow.
Pilot flame too large.
Adjust Unitrol pilot adjustment
screw.
Carbon build-up on thermopile
or thermocouple.
Remove and clean.
Содержание 14R
Страница 5: ......
Страница 9: ...NOTES...
Страница 10: ...SECTION 3S PARTS LIST MODEL 14R 18 WKS...
Страница 13: ...NOTES...
Страница 15: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...
Страница 16: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...
Страница 18: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...
Страница 19: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...
Страница 20: ...L20 310 R1 02 15...