background image

PITCO Frialator, Inc.

P.O. Box 501, Concord, New Hampshire 03301

1

1

2

2

4

4

6

6

TROUBLE

POSSIBLE CAUSE

REMEDY

Pilot flame burning yellow.

8

Draft may be pulling flame off 
thermopile or thermocouple.

7

Pressure at burner manifold 
should be 4.0" w.c. for natural 
gas and 10.0" w.c. for propane 
with all equipment on line in 
full operation. If this cannot be 
maintained, consult gas 
company.

Gas pressure too low.

8

7

Eliminate the draft.

Check millivoltage as above; 
increase size of flame with 
Unitrol pilot adjusting screw.

Remove and clean pilot and 
thermopile or thermocouple; 
decrease size of flame with 
Unitrol pilot adjusting screw if 
over 450 mv. Reading should 
be 500 +/-50 mv. for 
thermopile. Reading should be 
between 25 and 35  mv. for 
thermocouple. 

5

SECTION 2S TROUBLESHOOTING CHART

Thermopile or thermocouple 
producing insufficient 
millivoltage.

3

3

Pilot will light but Unitrol 
pilot gas valve will not hold 
open automatically.

Check all wire connections.

Loose wire connection in 
millivoltage circuit.

5

Hold Unitrol knob (in 

PILOT 

position) depressed for 1 
minute or longer. Make sure all 
air has been purged from gas 
line.

Pilot thermopile or 
thermocouple not hot enough 
to generate required 
millivoltage.

Check voltage at Unitrol with 
millivoltmeter, holding pilot 
flame on manually as in No. 1 
above. Reading should be 500 
+/-50 mv. for thermopile. 
Reading should be between 25 
and 35  mv. for thermocouple. 

Check continuity across limit 
control terminals with meter. If 
limit control has cut off, check 
at what temperature it cut off. 

Pilot flame too small.

High limit control may have cut 
out.

Содержание 14R

Страница 1: ...INC P O BOX 501 CONCORD N H 03301 PHONE 603 225 6684 SERVICE DEPT 603 225 5688 L20 310 R1 02 15 TROUBLESHOOTING MANUAL IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this m...

Страница 2: ...cedures Burner Flow Drawing Section 2S Troubleshooting Charts Section 3S Parts List Section 4S Front Panel Bezel Orifice Tips Burner Pressure Section 5S Entrance Box L20 310 R0 02 15 SERVICE MANUAL 14...

Страница 3: ...s are fastened to the inside of the heat tube by a small tack weld on the right hand front baffle support Break leg away from weld with a chisel or solid steel bar c Remove old baffles and insert new...

Страница 4: ...ned f Replace pilot orifice if desired flame cannot be obtained by adjustment See procedure 1 5 1 8 TO REPLACE LIMIT CONTROL a Turn Unitrol knob to OFF b Drain all shortening from fry tank Remove tube...

Страница 5: ......

Страница 6: ...ing should be between 25 and 35 mv for thermocouple 5 SECTION 2S TROUBLESHOOTING CHART Thermopile or thermocouple producing insufficient millivoltage 3 3 Pilot will light but Unitrol pilot gas valve w...

Страница 7: ...but burners will not light Pilot flame and main burners cut off while cooking 2 2 Pilot will light but Unitrol pilot gas valve will not hold open automatically Float switch bulb off or stuck down Inst...

Страница 8: ...place Unitrol Remove and clean cap 2 Call factory to learn proper sizes Remove burners and clean On natural gas adjust Unitrol pressure regulator to 4 0 w c operating pressure On propane gas have gas...

Страница 9: ...NOTES...

Страница 10: ...SECTION 3S PARTS LIST MODEL 14R 18 WKS...

Страница 11: ...P6071353 Burner Orifices Propane 18 See Orifice Chart See Section 3S Burner Orifices chart CE 12 A8001001 Air Collar 14 A8001101 Burner Fittings 15 B8005601 Manifold 17 PP10025 Main Burner Bolt 18 PP...

Страница 12: ...P 50 No 1 32 I3B P 50 No 1 25 GAS CATEGORY ORIFICE TIP SIZE mm GAS CATEGORY Supply Pressure mbars Governor on Gas Valve ORIFICE TIP SIZE mm I2H I2E I2E I2ESI 2 38 I3P 50 No 1 15 I2L 2 58 I3P 37 No 1 2...

Страница 13: ...NOTES...

Страница 14: ...Schematic 700131 Schematic 2 DS2 P5045044 Lamp S2 PP10093 Switch On Off S3 PP10559 Switch Start On Off DVI drain switch 4 K2 PP11124 Relay 24V SPDT DC 10 K3 P5046686 Relay 24V DPDT AC B6711702 Harness...

Страница 15: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...

Страница 16: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...

Страница 17: ...115V B2904504 Entrance Box 220 240V 1 P5045794 Fuseholder PP10122 1 Amp Fuse 115V P5045717 2 Amp Fuse 220 240V 1 P5045794 Fuseholder 1 PP10122 1 Amp Fuse 115V 4 1 PP10210 40VA Transformer B6713901 Wir...

Страница 18: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...

Страница 19: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...

Страница 20: ...L20 310 R1 02 15...

Отзывы: