ENGLISH
25
ELECTRICAL WIRE DIAGRAM
The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 60HZ, 250W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
FUEL INPUT
RATING:
1.0 KG/H
(2.2 LB/H)
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
P
P
R
Y
Y
Y
P
K
K
W
G
W
W
W
R R
W
W
W
W
Y
Y
K
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
200W, 120V, 2.6 AMP
0.375” X 5.000”
FIRE POT
DRAFT FAN
120V, 50/60HZ,
0.1 AMP, 1 PSHASE
GROUNDED
POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
AUGER MOTOR
& FEED SYSTEM
120V, 50/60HZ,
0.22 AMP, 2 RPM MOTOR
GROUND
GRILL
PROBE
TEMPERATURE PROBE
MOLEX CONNECTOR
FAST-BLOW FUSE
5 AMP
CONTROL BOARD
To gain access to the electrical components,
first locate and remove the EIGHT SCREWS on
the underside of the side shelf. Set screws and
pieces aside.
Next locate and remove the TEN SCREWS
on the underside of the main grill body. Set
screws and pieces aside. Perform electrical
maintenance required.
k
j