PISLA HTT
DEEP FOREST ECO, SPARKS ECO
PISLA OY
| Teollisuustie 6-8 | FI 44500 VIITASAARI | +358 10 843 210 | www.pisla.fi
6. Products are covered by a harmonized standard:
EN 13240:2001 /A2:2004/AC:2007, assessment under the 3, made by:
Engineering Testing Institute, Public Enterprise, Hudcova 424/56b, CZ-621 00 Brno, notified body 1015 and issued by:
▪
INITIAL PRODUCT TEST REPORT, Nr. 30-15802/T, of the day 2022-01-21
▪
REPORT on the Assessment of the Performance of the Construction product, Nr. 1015-CPR-30-15802/TZ, of the day
2022-02-10
▪
EVALUATION REPORT, Nr. 30-15802/TH, of the day 2022-01-24
7. Declared features specified in the declaration apply to all products listed in paragraph 2:
Harmonized technical specification
EN 13240:2001/A2:2004/AC:2007
Main features
features
Fire safety - Reaction to fire
A1
Distance from flammable materials
Minimal distance [mm]:
• rear wall =
400
• side walls =
400
for DEEP FOREST ECO and SPARKS ECO
• ceiling = 1500
• front = 800
Risk of burning fuel falling
Requirement fulfilled
The emissions
• CO [%]: wood=0.05, brown coal
briquettes=0.09
• CO [mg/Nm
3
]: wood=630, brown coal briquettes=1110
• Dust [mg/Nm
3
]: wood=35, brown coal briquettes=33
• OGC [mg/Nm
3
]: wood=24, brown coal briquettes=49
• NOx [mg/Nm
3
]: wood=104, brown coal briquettes=187
The surface temperature
Requirement fulfilled
Electrical safety
NPD
Clean ability
Requirement fulfilled
Max. operational pressure
NPD
Flue gas temperature at rated thermal output
T [°C]: wood=243, brown coal briquettes =221
Mechanical resistance (load flue connection)
Requirement fulfilled
Nominal output
6.5 kW
Space heating performance
6.7 kW
Heat capacity of water
NPD
Seasonal space heating energy efficiency in active
mode
η
s,on
[%]: wood=83.5, brown coal briquettes =77.7
Seasonal space heating energy efficiency
η
s
[%]: wood=73.5, brown coal briquettes =67.7
8. Product features (of the products) of paragraph 1 and 2 are consistent with the characteristics listed in
paragraph 7.
The declaration of features is issued under the sole responsibility of the manufacturer referred to in paragraph 4.