![PISCO VJ Series Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/pisco/vj-series/vj-series_manual_1559163042.webp)
Energy saving sensor (DWE) Instruction manual
According to panel operation procedure ①
of selection mode for panel operation procedure,
input auto preset in the selection mode
Set with (▼)or(▲) button If set,
press (▼)and(▲) simultaneously for 1 second
to fix and return to selection mode
Set with (▼)or(▲) button If set,
press (▼)and(▲) simultaneously for 1 second
to fix and return to selection mode
Hd : Manual setting mode
Au : Automatic setting mode
※Press (▼) and (▲) simultaneously for 2 second
to Confirm / Save and return to operation mode
oF : Copy plug OFF
on : Copy plug ON
※Press (▼) and (▲) simultaneously for 2 second
to Confirm / Save and return to operation mode
[Automatic setting mode]
Select automatic selection mode and enter operation mode (Display pressure)
Press (▲) and hold for 1 second will flash "PA".
Move the device and repeat adsorption and exhaust (Repeated time irrelevant )
Calculate P1 ~ H2 according to the method on the right (return the plug to "Hd")
Set value confirmed. Return to operation mode (pressure display)
[Copy plug "on" explaination]
Use COMMAND terminal to connect sensor(10*max) before copying
Set the master (sending side) sensor to copy mode and set it to transmit mode (copy plug ON)
Restarting power will blink "CO" and sends reset pulse from the master. When the operator confirms the ready indication "Py" of the
slave(receiving side), the master (1) button is pressed for 1 second, "CO" flashes to start transmission and reception of the copy.
Slave which completed satisfactorily will blink "Ed". Press (▼)button to return to operation mode.
Copying can be continued by swapping the slave side and restarting the entire power.
After completing copying, press (▼)button for more than 1 second to cancel copy mode.
42
A : MAX reach pressure
B : MIN reach pressure
※ Pressure detection condition
: -10kPa or less
[Set value]
According to panel operation procedure ①
of selection mode for panel operation procedure,
input auto preset in the selection mode