Chemical Name

Thinner

Carbon tetrachloride

Chloroform

Acetate

Aniline

Cyclohexane

Trichloroethylene

Sulfuric acid

Lactic acid

Water soluble cutting oil (alkaline)

* There are more chemicals which should be avoided. Contact us for the use under chemical circumstance.

 Caution

1. Operating pressure range in the catalog is the values during ejector operation.

Secure  the  described  value  of  the  supplied  air,  taking  a  drop  of  the  pressure

into  consideration.  Insufficient  pressure,  which  does  not  satisfy  the  spec,

may  cause  abnormal  noise,  unstable  performance  and  may  negatively  affect

sensors, bringing troubles at last.

2. Effective cross-section area of the air supply side needs to be three times as

large as effective cross-section area of the nozzle bore. When arranging piping

or  selecting  PISCO  products,  secure  required  effective  cross-section  area.

Insufficient supply pressure may be a cause to impair performance.

3. A  Shorter  distance  of  plumbing  with  a  wider  bore  is  preferable  at  vacuum

system  side.  A  long  plumbing  with  a  small  bore  may  result  in  slow  response

time at the time of releasing work-piece as well as in failure to secure adequate

suction flow rate.

4. Plumb  a  vacuum  switch  and  an  ejector  with  vacuum  switch  at  the  end  of

vacuum  system  as  much  as  possible.  A  long  distance  between  a  vacuum

switch  and  a  vacuum  system  end  may  increase  plumbing  resistance  which

may lead to a high vacuum level at the sensor even when no suctioning and a

malfunction of vacuum switch. Make sure to evaluate the products in an actual

system.

5. Refer  to  “4.  Instructions  for  Installing  a  fitting”  and  “5.  Instructions  for

Removing  a  fitting”  under  “Common  Safety  Instructions  for  Fittings” ,  when

installing or removing Fittings.

6. Refer  to  “Common  Safety  Instructions  for  Pressure  Sensors”  and  “Detailed

Safety Instructions” for the handling of digital vacuum switch sensor.

7. Refer to “Common Safety Instructions for Mechanical Vacuum Sensor” for the

handling of mechanical vacuum switch.

8. The material of plastic filter cover for VG, VK, VJ, VZ and VX series is PCTG.

Avoid the adherence of Chemicals below to the products, and do not use them

under those chemical environments.

●Table  Chemical Name

17. Do not use the product in the environment of inflammable or explosive gas /

fluid. It can cause a fire or an explosion hazard.

18. Do  not  use  the  product  in  the  circumstance  of  corrosive  gas,  inflammable

gas,  explosive  gas,  chemicals,  seawater  and  vapor  or  do  not  expose  the

product to those. Otherwise, it may be a cause of malfunction.

19. Do not clean or paint the products by water or a solvent.

http://

www.pisco.com

Содержание FH10

Страница 1: ...30 15 Make to order products Vacuum Cup Ball Swiveling Attachment Swivel Joint Suitable for sucking work pieces with non vertical position or with unfixed angle http www pisco com ...

Страница 2: ...urling part of FH10 and FH20 or use a spanner to tighten the parallel cut part of FH60 Refer to the dimensional drawings of the parallel cut part Code Pad size mm 10 ø10 ø15 Code Oscillatingangle No code 30 ー 15 15 option 20 ø20 ø50 4 10 8 30 60 ø60 ø100 Holder size code 20 is applicable for pad size ø10mm and ø15mm for sponge series due to the structural reasons FH10 and FH20 FH60 ...

Страница 3: ...ressure Otherwise the work piece may drop from the vacuum pad during transportation and there is a possibility of damaging the holder 3 Avoid any excessive pressure on Free Holder Otherwise there is a possibility of damaging the holder Caution 1 Pay special attention to the angle position of Free Holder The angle position can be changed after sucking work piece by work piece weight and acceleratio...

Страница 4: ...sh In Fitting VPD Push In Fitting VPF Push In Fitting Holder model code FH 10 Pad dia ø10 15mm Free Holder Pad dia ø10mm ø15mm Standard Series Pad dia ø10mm Bellows Series compliant Unit mm Model code M1 M2 A1 A2 B L1 L2 øP Hex H1 Hex H2 Weight g CAD file name FH10 M4 0 7 M4 0 7 3 4 7 23 19 6 11 1 15 4 9 VVP 229 FH20 M6 1 M6 1 6 6 5 28 5 22 5 12 5 20 7 19 5 FH60 M10 1 5 M10 1 5 10 9 5 40 5 30 5 18...

Страница 5: ... Barb Fitting VPB Barb Fitting VPC Barb Fitting VPD Barb Fitting VPB Push In Fitting VPC Push In Fitting VPD Push In Fitting VPF Push In Fitting Pad dia ø20mm ø25mm ø30mm ø40mm ø50mm Standard Series Pad dia ø20mm ø30mm ø40mm ø50mm Skidproof Series Pad dia ø10mm ø15mm ø20mm ø25mm ø30mm Sponge Series Pad dia ø35mm ø50mm Sponge Series Pad dia ø20mm ø30mm ø40mm ø50mm Bellows Series Pad dia 4 10 20 30m...

Страница 6: ...female thread VPB Parallel female thread VPC Parallel female thread VPD Parallel female thread Model code FH 60 Pad dia ø60 70 80 100mm Swivel Joint Pad dia ø60mm Standard Series Pad dia ø80mm ø100mm Standard Series Pad dia ø80mm Bellows Series Pad dia ø70mm ø100mm Sponge Series ...

Страница 7: ...PISCO products and constitute all systems based on the latest catalog or information considering any malfunctions 2 Handle the pneumatic equipment with enough knowledge and experience Improper use of compressed air is dangerous Assembly operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience 3 Do not operate machine equip...

Страница 8: ...accidental damages of PISCO products due to incorrect usage 3 PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow 4 PISCO does not take any responsibility for any loss caused by remodeling of PISCO products or by combinational use with non PIS...

Страница 9: ...uit Rotary Block only The other PISCO products can be damaged in these applications 8 Use only Die Temperature Control Fitting Series Tube Fitting Stainless SUS316 Series Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting Brass Series under the condition of over 60 140 F water or thermal oil Other PISCO products can be damaged by heat and hydrolysis under the condition above ...

Страница 10: ...ch size Nylon tube Polyurethane tube ø1 8mm 0 05mm ø1 8 0 1mm 0 15mm ø3mm 0 15mm ø5 32 0 1mm 0 15mm ø4mm 0 1mm 0 15mm ø3 16 0 1mm 0 15mm ø6mm 0 1mm 0 15mm ø1 4 0 1mm 0 15mm ø8mm 0 1mm 0 15mm ø5 16 0 1mm 0 15mm ø10mm 0 1mm 0 15mm ø3 8 0 1mm 0 15mm ø12mm 0 1mm 0 15mm ø1 2 0 1mm 0 15mm ø16mm 0 1mm 0 15mm ø5 8 0 1mm 0 15mm 6 Instructions for Tube Insertion Make sure that the cut end surface of the tub...

Страница 11: ...thread or a fluid leakage Adjust the tube direction while tightening thread within these limits since some PISCO products are not rotatable after the installation Table 2 Recommended tightening torque Sealock color Gasket materials Thread type Thread size Tightening torque Sealock color Gasket materials Metric thread M3 0 5 0 7N m SUS304 NBR M5 0 8 1 0 1 5N m M6 1 2 2 7N m M3 0 5 0 5 0 6N m POM M5...

Страница 12: ...de a protective cover on the products when it is exposed to sunlight 8 Carry out clogging check for silencer element in an ejector and a vacuum filter periodically Clogged element will be a cause to impair the performance or a cause of troubles 9 Before replacing the element thoroughly read and understand the method of filter replacement in the catalog 10 Make sure the correct port of the vacuum g...

Страница 13: ...an ejector with vacuum switch at the end of vacuum system as much as possible A long distance between a vacuum switch and a vacuum system end may increase plumbing resistance which may lead to a high vacuum level at the sensor even when no suctioning and a malfunction of vacuum switch Make sure to evaluate the products in an actual system 5 Refer to 4 Instructions for Installing a fitting and 5 In...

Страница 14: ...drogen peroxide Vacuum Generator Series 9 The material of plastic filter cover for VQ and VFU series is PA Avoid the adherence of chemicals below to the products and do not use them under those chemical environments Table Chemical Name There are more chemicals which should be avoided Contact us for the use under chemical circumstance ...