PISCO FH10 Скачать руководство пользователя страница 12

 Vacuum Generator 

Series

 Common Safety Instructions for Vacuum Series

 Warning

Before selecting or using PISCO products, read the following instructions. Read the 
detailed instructions for individual series.

1. If there is a risk of dropping work-pieces during vacuum suction, take a safety

measure against the falling of them.

2. Avoid supplying more than 0.1MPa pressure constantly in a vacuum circuit.

Since vacuum generators are not explosive-proof, there is a risk of damaging

the products.

3. Pay attention to drop of vacuum pressure caused by problems of the supplied

air  or  the  power  supply.  Decrease  of  suction  force  may  lead  to  a  danger

of  falling  work-piece  so  that  safety  measure  against  the  falling  of  them  is

necessary.

4. When more than 2 vacuum pads are plumbed on a single ejector and one of

them has a suction problem such as vacuum leak, there is a risk of releasing

work-pieces from the other pad due to the drop of the vacuum pressure.

5. Do not use in the way by which exhaust port is blocked or exhaust resistance

is increased. Otherwise, there is a risk of no vacuum generation or a drop of

the vacuum pressure.

6. Do  not  use  the  product  in  the  circumstance  of  corrosive  gas,  inflammable

gas,  explosive  gas,  chemicals,  seawater  and  vapor  or  do  not  expose  the

product to those. Never allow the product to suck those things.

7. Provide a protective cover on the products when it is exposed to sunlight.

8. Carry  out  clogging  check  for  silencer  element  in  an  ejector  and  a  vacuum

filter periodically. Clogged element will be a cause to impair the performance

or a cause of troubles.

9. Before replacing the element, thoroughly read and understand the method of

filter replacement in the catalog.

10. Make  sure  the  correct  port  of  the  vacuum  generator  by  this  catalog  or

marking  on  the  products  when  plumbing.  Wrong  plumbing  can  be  a  risk  to

damage the product.

11. Supply clean air without sludge or dusts to an ejector. Do not lubricate by a

lubricator. There is a risk of malfunction or performance impairing by impurities

and oil contained in the compressed air.

12. Do  not  apply  extreme  tension,  twist  or  bending  forces  on  a  lead  wire.

Otherwise, it may cause a wire breaking.

13. Locknut needs to be tightened firmly by hand. Do not use any tool to tighten.

In case of using tools to tighten the locknut, it may damage the locknut or the

product. Inadequate tightening may loosen the locknut and the initial setting

can be changed.

14. Do not force the product to rotate or swing even its resin body is rotatable. It

may cause damage to the product and a fluid leakage.

15. Do not supply an air pressure or a dry air to the products over the necessary

amount. There is a risk of deteriorating rubber materials and malfunction due

to oil.

16. Keep  the  product  away  from  water,  oil  drops  or  dusts.  These  may  cause

malfunction.  Take  a  proper  measure  to  protect  the  product  before  the

operation.

Содержание FH10

Страница 1: ...30 15 Make to order products Vacuum Cup Ball Swiveling Attachment Swivel Joint Suitable for sucking work pieces with non vertical position or with unfixed angle http www pisco com ...

Страница 2: ...urling part of FH10 and FH20 or use a spanner to tighten the parallel cut part of FH60 Refer to the dimensional drawings of the parallel cut part Code Pad size mm 10 ø10 ø15 Code Oscillatingangle No code 30 ー 15 15 option 20 ø20 ø50 4 10 8 30 60 ø60 ø100 Holder size code 20 is applicable for pad size ø10mm and ø15mm for sponge series due to the structural reasons FH10 and FH20 FH60 ...

Страница 3: ...ressure Otherwise the work piece may drop from the vacuum pad during transportation and there is a possibility of damaging the holder 3 Avoid any excessive pressure on Free Holder Otherwise there is a possibility of damaging the holder Caution 1 Pay special attention to the angle position of Free Holder The angle position can be changed after sucking work piece by work piece weight and acceleratio...

Страница 4: ...sh In Fitting VPD Push In Fitting VPF Push In Fitting Holder model code FH 10 Pad dia ø10 15mm Free Holder Pad dia ø10mm ø15mm Standard Series Pad dia ø10mm Bellows Series compliant Unit mm Model code M1 M2 A1 A2 B L1 L2 øP Hex H1 Hex H2 Weight g CAD file name FH10 M4 0 7 M4 0 7 3 4 7 23 19 6 11 1 15 4 9 VVP 229 FH20 M6 1 M6 1 6 6 5 28 5 22 5 12 5 20 7 19 5 FH60 M10 1 5 M10 1 5 10 9 5 40 5 30 5 18...

Страница 5: ... Barb Fitting VPB Barb Fitting VPC Barb Fitting VPD Barb Fitting VPB Push In Fitting VPC Push In Fitting VPD Push In Fitting VPF Push In Fitting Pad dia ø20mm ø25mm ø30mm ø40mm ø50mm Standard Series Pad dia ø20mm ø30mm ø40mm ø50mm Skidproof Series Pad dia ø10mm ø15mm ø20mm ø25mm ø30mm Sponge Series Pad dia ø35mm ø50mm Sponge Series Pad dia ø20mm ø30mm ø40mm ø50mm Bellows Series Pad dia 4 10 20 30m...

Страница 6: ...female thread VPB Parallel female thread VPC Parallel female thread VPD Parallel female thread Model code FH 60 Pad dia ø60 70 80 100mm Swivel Joint Pad dia ø60mm Standard Series Pad dia ø80mm ø100mm Standard Series Pad dia ø80mm Bellows Series Pad dia ø70mm ø100mm Sponge Series ...

Страница 7: ...PISCO products and constitute all systems based on the latest catalog or information considering any malfunctions 2 Handle the pneumatic equipment with enough knowledge and experience Improper use of compressed air is dangerous Assembly operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience 3 Do not operate machine equip...

Страница 8: ...accidental damages of PISCO products due to incorrect usage 3 PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow 4 PISCO does not take any responsibility for any loss caused by remodeling of PISCO products or by combinational use with non PIS...

Страница 9: ...uit Rotary Block only The other PISCO products can be damaged in these applications 8 Use only Die Temperature Control Fitting Series Tube Fitting Stainless SUS316 Series Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting Brass Series under the condition of over 60 140 F water or thermal oil Other PISCO products can be damaged by heat and hydrolysis under the condition above ...

Страница 10: ...ch size Nylon tube Polyurethane tube ø1 8mm 0 05mm ø1 8 0 1mm 0 15mm ø3mm 0 15mm ø5 32 0 1mm 0 15mm ø4mm 0 1mm 0 15mm ø3 16 0 1mm 0 15mm ø6mm 0 1mm 0 15mm ø1 4 0 1mm 0 15mm ø8mm 0 1mm 0 15mm ø5 16 0 1mm 0 15mm ø10mm 0 1mm 0 15mm ø3 8 0 1mm 0 15mm ø12mm 0 1mm 0 15mm ø1 2 0 1mm 0 15mm ø16mm 0 1mm 0 15mm ø5 8 0 1mm 0 15mm 6 Instructions for Tube Insertion Make sure that the cut end surface of the tub...

Страница 11: ...thread or a fluid leakage Adjust the tube direction while tightening thread within these limits since some PISCO products are not rotatable after the installation Table 2 Recommended tightening torque Sealock color Gasket materials Thread type Thread size Tightening torque Sealock color Gasket materials Metric thread M3 0 5 0 7N m SUS304 NBR M5 0 8 1 0 1 5N m M6 1 2 2 7N m M3 0 5 0 5 0 6N m POM M5...

Страница 12: ...de a protective cover on the products when it is exposed to sunlight 8 Carry out clogging check for silencer element in an ejector and a vacuum filter periodically Clogged element will be a cause to impair the performance or a cause of troubles 9 Before replacing the element thoroughly read and understand the method of filter replacement in the catalog 10 Make sure the correct port of the vacuum g...

Страница 13: ...an ejector with vacuum switch at the end of vacuum system as much as possible A long distance between a vacuum switch and a vacuum system end may increase plumbing resistance which may lead to a high vacuum level at the sensor even when no suctioning and a malfunction of vacuum switch Make sure to evaluate the products in an actual system 5 Refer to 4 Instructions for Installing a fitting and 5 In...

Страница 14: ...drogen peroxide Vacuum Generator Series 9 The material of plastic filter cover for VQ and VFU series is PA Avoid the adherence of chemicals below to the products and do not use them under those chemical environments Table Chemical Name There are more chemicals which should be avoided Contact us for the use under chemical circumstance ...

Отзывы: