EQ
Unit
:
mm
Model code
Tube O.D.
øD1
Tube O.D.
øD2
R
A
B
L1
L2
Tube end
C1
Tube end
C2
E1
E2
□
F
Effective area(mm
2
) Weight
(g)
CAD
file name
IN
→
OUT OUT
→
EX
EQ01-C04P01C08
4
8
1/8
8
25.5 21.5
14
10.9
18.2
46.5 23.8
15
4
9
19
CRE-001
EQ01-C06P01C08
6
11.7
46.8 24.1
6
EQ02-C06P01C10
6
10
1/8
8
29
25
16
11.7
20.7
54.4 28.1
18
9
16
27
EQ02-C06P02C10
1/4
11
31
29
EQ02-C08P01C10
8
1/8
8
29
18.2
59.7 33.4
12
31
EQ02-C08P02C10
1/4
11
31
33
EQ03-C10P02C12
10
12
1/4
11
40.5
34.5
22
20.7
23.3
74.6 42.8
25
24
34
69
EQ03-C10P03C12
3/8
12
34.2 21.7
25
35
72
EQ03-C10P04C12
1/2
15
42.5 34.3 21.8
27
37
77
EQ03-C12P02C12
12
1/4
11
40.5
34.5
22
23.3
76.2 44.4
25
34
73
EQ03-C12P03C12
3/8
12
34.2 21.7
26
35
75
EQ03-C12P04C12
1/2
15
42.5 34.3 21.8
28
37
80
※
.
“
L1
”
and
“
L2
”
are reference values for height dimensions after tightening taper thread.
R
øD1
øD2
B
L1
L2
A
IN & EX port: Fitting OUT port: Thread
(Tube exhaust)
E1
E2
C1
C2
□
F
■ Standard type
compliant
Detailed Safety Instructions
Before using PISCO products, be sure to read “Safety Instructions” and “Safety
Instruction Manual” and “Common Safety Instructions for Controllers”
Warning
1.
When controlling the speed of actuators with needle type, slowly release the air by adjusting
the needle from a fully closed state. In case the needle is opened, actuator can move
suddenly. As for other tha
n
needle type
s
, make sure to confirm the safety before operation.
2.
Do not swing or rotate resin body of the products by force. It may damage to the
products and cause a fluid leakage.
Caution
1.
The clogging of silencer element increases exhaust-resistance. There is a possibility that it
causes the system
malfunction
.
2.
Make sure to provide a differential pressure when Quick Exhaust Valve is used as a
shuttle valve. It can cause a malfunction without the differential pressure.
3.
When replacing a silencer element, make sure to place the silencer cover over the
element and tighten the cover by hand firmly.
T
he element
for
mini type
, E
QE
can not be replaced
.
4.
Use a proper tool to tighten a hexagonal-column or square part of Quick Exhaust Valve. Refer
to “2. Instructions for Installing Controllers” in “Common Safety Instructions for Controllers”.
5.
Adjust the tube direction while tightening thread within the tightening torque limits, since
some PISCO products
do
not
swivel
after the installation.
6.
Exhaust air dirt may adhere to Exhaust port area (around outer hexagonal thread) of EQH
(Exhaust
needle type
)
and become discolored depending on the use conditions and use
frequency, but it is not
a