-8-
„SHORTED“
The atomizer was shorted by sliping as well as
burning out the coil or by loose connections
(threads, fittings) inside the atomizer during
firing. In this case the power output will be
locked automatically.
Check your atomizer for mechanical short-
ing and your coil for sliping or burning!
„WEAK BATTERY“
The inserted battery is nearly discharged or the
requested voltage cannot be delivered by the
battery (excessive voltage drop in case of
overload). In this case the power output
automatically will be throttled down to a save
level to protect the battery.
Check your battery for compatibility
(discharge current of 20 amps
–
unprotected) and as appropriate, charge
your battery with a suitable external
charger or use the included Micro-USB
charging lead!
(>> Operating)
„CHECK BATTERY“
The inserted battery is completely discharged
(reaching the lower cut-off voltage) or
exhausted. In this case the power output will be
locked automatically to avoid progressing
discharge of the battery.
Check your battery for exhaustion (battery
can‘t be charged anymore, can’t hold the
charge or discharge very quickly) and as
appropriate, charge your battery with a
suitable external charger or use the
included USB charging lead!
(>> Operating)
„TEMPERATURE PROTECTED“
The selected temperature
[C
│
F]
was reached
during firing. In this case the power output
automatically will be throttled down to a save
level until the temperature dropping below the
selected value.
First check the selected temperature of
the device and as appropriate, increase it.
If the temperture is already set correctly
decrease the power output
[W]
of the
device until the selceted temperature
won‘t be reached anymore!
(>> Advanced Operating)
„OHMS TOO HIGH“
The resistance of the atomizer coil
[Ω]
is too high
for the current power setting
[W]
. In this case the
power output automatically will be throttled
down to the next approachable value.
Decrease the power output (W) of the
device
until the error massage won’t
appear anymore during firing or
alternatively check the coil resistance and
as appropriate, install a new coil with lower
resistance!
(>> Specifications)
„OHMS TOO LOW“
The resistance of the atomizer coil
[Ω]
is too low
for the current power setting
[W]
. In this case the
power output automatically will be throttled
down to the next approachable value.
Decrease the power output
[W]
of the
device until the error massage won’t
appear anymore during firing or
alternatively check the coil resistance and
as appropriate, install a new coil with
higher resistance!
(>> Specifications)