03 MAIN MENU

Temperature Up and Temperature Down 
(Temperature Adjustment)

These menu items are visible only when the temperature control 
is enabled (see Mode menu).  

 The menu items allow you to set the maximum temperature for tem-
perature controlled vaping in 5 ° C increments from 120 ° C to 280 ° 
C (or 250 ° F - 540 ° F). For precise control you need the atomizer to 
be at room temperature (about 20 ° C) Calibration (Calibr). For this 
purpose a suitable wire with a high temperature coefficient is nee-
ded. Enter the temperature coefficient of the wire in the Extended 
Functions submenu> Temp menu> Temp Cof.

Factory setting: 190 ° C

Mode

The PIPELINE PRO 2 PLUS provides 5 different modes 
that can be selected in this menu

Power (VW), TmpCtrl (Temperature-Controlled vaping), PowerHP (VW 
with Heat Protection activated), PowerBO (VW with Power Boost acti-
vated), and Bypass (unregulated mode, electronic overload protec-
tion). You can disable the „Expert Mode“ in the extended functions 
menu (> System menu) PowerHP, PowerBO and Bypass disable.

If you select temperature controlled vaping (TmpCtrl), after 
2 seconds the display will show „Wire320“ on the top line.
There you can choose a suitable wire for temperature controlled 
vaping. 320 stands for the set temperature coefficient of the wire. 
This varies on the top line according to the type of wire selected.

Choose from the following types of wire:

If you select „Other“, you must manually enter the temperature 
coefficient of the wire in the extended functions menu (>Temp 
Menu>Temp Cof). 

Factory setting: Power

Switching Off the PIPELINE PRO 2 PLUS

In addition to the auto-shutdown the user can turn off the power 
manually. We recommend the unit is switched off before changing 
the battery, only then are the statistics stored, otherwise the changes 
since the last save will be lost by removing the battery.

Extended Functions Menu

The „Extended Functions“ menu has 3 sub-menus:

- Temp Menu> Settings for the coil
- System Menu> Settings to customize the PIPELINE PRO 2 PLUS
- Info Menu> Statistical display

Calibration 
(Manual Coil Temperature Calibration)

These menu items are visible only when the temperature control is 
enabled (see Mode menu). The calibration measures the coil 
resistance as a reference value for the temperature control, this 
should only be done at room temperature (20 ° C). The calibration 
is a process with 3 steps: Init, Confirm and Process. Each of these 3 
steps must be confirmed by pressing the button, so that the 
calibration is actually executed. We recommend heating the coil to 
the “evaporation phase“ a second time to calibrate , since the 
resistance of the wire may vary.

Coil resistance and temperature

In this menu item, the resistance (R) of the coil is shown. 
The display ranges from 0.0Ω to 9.90Ω.  

When temperature controlled vaping is enabled,  
the actual temperature of the heating coil is also displayed (T).

Battery Status

The „Battery Status“ shows the battery voltage with low current drain 
(Bat) and the battery voltage under load of the atomizer used (BatL). 
If the difference between the two values   shows a strong drop in the 
voltage this is an indication of a low battery or contact problems.

Stainless Steel Wire

Other Wire

Tungsten Wire

Titanium Wire

Nickel Wire Ni200

Resistherm Wire