03 MAIN MENU
Temperature Up and Temperature Down
(Temperature Adjustment)
These menu items are visible only when the temperature control
is enabled (see Mode menu).
The menu items allow you to set the maximum temperature for tem-
perature controlled vaping in 5 ° C increments from 120 ° C to 280 °
C (or 250 ° F - 540 ° F). For precise control you need the atomizer to
be at room temperature (about 20 ° C) Calibration (Calibr). For this
purpose a suitable wire with a high temperature coefficient is nee-
ded. Enter the temperature coefficient of the wire in the Extended
Functions submenu> Temp menu> Temp Cof.
Factory setting: 190 ° C
Mode
The PIPELINE PRO 2 PLUS provides 5 different modes
that can be selected in this menu
Power (VW), TmpCtrl (Temperature-Controlled vaping), PowerHP (VW
with Heat Protection activated), PowerBO (VW with Power Boost acti-
vated), and Bypass (unregulated mode, electronic overload protec-
tion). You can disable the „Expert Mode“ in the extended functions
menu (> System menu) PowerHP, PowerBO and Bypass disable.
If you select temperature controlled vaping (TmpCtrl), after
2 seconds the display will show „Wire320“ on the top line.
There you can choose a suitable wire for temperature controlled
vaping. 320 stands for the set temperature coefficient of the wire.
This varies on the top line according to the type of wire selected.
Choose from the following types of wire:
If you select „Other“, you must manually enter the temperature
coefficient of the wire in the extended functions menu (>Temp
Menu>Temp Cof).
Factory setting: Power
Switching Off the PIPELINE PRO 2 PLUS
In addition to the auto-shutdown the user can turn off the power
manually. We recommend the unit is switched off before changing
the battery, only then are the statistics stored, otherwise the changes
since the last save will be lost by removing the battery.
Extended Functions Menu
The „Extended Functions“ menu has 3 sub-menus:
- Temp Menu> Settings for the coil
- System Menu> Settings to customize the PIPELINE PRO 2 PLUS
- Info Menu> Statistical display
Calibration
(Manual Coil Temperature Calibration)
These menu items are visible only when the temperature control is
enabled (see Mode menu). The calibration measures the coil
resistance as a reference value for the temperature control, this
should only be done at room temperature (20 ° C). The calibration
is a process with 3 steps: Init, Confirm and Process. Each of these 3
steps must be confirmed by pressing the button, so that the
calibration is actually executed. We recommend heating the coil to
the “evaporation phase“ a second time to calibrate , since the
resistance of the wire may vary.
Coil resistance and temperature
In this menu item, the resistance (R) of the coil is shown.
The display ranges from 0.0Ω to 9.90Ω.
When temperature controlled vaping is enabled,
the actual temperature of the heating coil is also displayed (T).
Battery Status
The „Battery Status“ shows the battery voltage with low current drain
(Bat) and the battery voltage under load of the atomizer used (BatL).
If the difference between the two values shows a strong drop in the
voltage this is an indication of a low battery or contact problems.
Stainless Steel Wire
Other Wire
Tungsten Wire
Titanium Wire
Nickel Wire Ni200
Resistherm Wire