9
!
危
险
!
·
Wrap t
ape material along the wire
and
seal wiring holes,
to
prevent
entrance of c
ondensed water and insects.
·
Tightly
secure
the
power
source
wiring using
the
cord
clamp
inside
the
unit
.
Note: Fix
the
rubber
bushes
with
adhesive
when conduit
tubes
to
the
outdoor
unit
are
not
used
.
General
C
heck
(1)
Make
sure
that
the
field
-
selected
electrical components
(
main
power
switches
,
circuit breakers
,
wires
,
conduit
connectors
and
wire
terminals
)
have
been
properly selected
according
to
the
electrical
data
.
Make
sure
that
the
components
comply with
National
Electrical
Code
(
NEC
).
(2)
Check
to
ensure
that
the
voltage
of
power supply
is
within
+
10
%
of
nominal
voltage and
earth
phase
is
contained
in
the
power supply
wires
.
If
not
,
electrical
parts
can
be damaged
.
(3)
Check
to
ensure
that
the
capacity
of
power supply
is
enough
.
If
not
,
the
compressor
will
be
not
able
to operate
due to abnormal
voltage
drop at
start
up
.
(4)
Check
to
ensure
that
the
earth
wire
is connected
.
(5)
Install
a
main
switch
,
multi
-
pole
main
switch
,
with
a
space
of
0.14 in. (3.5mm)
or
more, single
-
p
hase
main
switch
with
a
space
of 0.12 in. (3.0mm) or
more
between
each
phase
.
(6)
Check
to
ensure
that
the
electrical resistance
is
more
than
2
M
Ω,
by measuring
the
resistance
between
ground and
the
terminal
of
the
electrical
parts
.
If
not
,
do
not
operate
the
system
until
the electrical
leakage
is
located
and
repaired
.
·
Turn
OFF
the
main
power
switch
to
the
indoor
unit
and
the
outdoor
unit
,
and
wait
for
at least
3
minutes
before
electrical
wiring work
or
a
periodical
check
is
performed
.
·
Check
to
ensure
that
the
indoor
fan
and
the outdoor
fan
have
stopped
,
before
electrical
wiring
work
or
a
periodical
check
is
performed
.
·
Protect
the
wires
,
electrical
parts
,
etc
.
from rats
or
other
small
animals
.
If
not
protected
,
rats
may
gnaw
at
unprotected
parts
and
in the
worst
-case scenario
,
a
fire will
occur
.
·
Prevent
the
wirings
from
touching
the
refrigerant
pipes
,
plate
edges
,
and
electrical parts
inside
the
unit
.
If
not
do
ne so
,
the
wires
will
be
damaged
and
in
the
worst
-case scenario
,
a
fire
will
occur
.
·
Install
an
ELB
(Electric Leakage Break)
at
the
power
source
.
If
an
ELB
is
not
used
,
it
can
cause
electric
shock
or fire
at
the
worst
-case scenario
.
·
This
unit
uses
an
inverter
,
which
means
that
it
must
use
an
earth
leak
detector
capable
of
hand
l
ing
harmonics
in
order
to
prevent
malfunctioning
of
the
earth
leak
detector
itself.
·
Do not use intermediate connection wires, stranded wires(see
Attentions
when
Connect
ing
the
P
ower
S
upply
W
iring
),
extension cables or control line connection,
as
the use of these wires may
cause
unwanted heat
, electric
shock
,
or fire.
·
The tightening torque of each screw shall be as follows.
M4
:
0.7
to
1.0
lb
f
·
ft
.
(1
.
0
to
1
.
3
N
·
m)
M5
:
1.5 to 1.8 lb
f
·
ft
.
(2
.
0
to
2
.
5
N
·
m)
M6
:
3.0 to 3.7 lb
f
·
ft
.
(4
.
0
to
5
.
0
N
·
m)
M8
:
6.6 to 8.1 lb
f
·
ft
.
(9
.
0
to
11
.
0
N
·
m)
M10
:
13.3 to 217 lb
f
·
ft
.
(18
.
0
to
23
.
0
N
·
m)
Keep
the
above
tightening
torque
values in mind
when
performing
wiring
work
.
WARNING
CAUTION
Installation
I
nstructions
Wiring