7.1.10 SEQUENCE AFTER POWER ON/0FF
1
Power ON
•
There are two kinds of Power ON: "Normal Power ON" and "Display Only Power ON".
•
Normal Power ON
Power On operated when the Power button or the Play Pause button is pressed during standby
or operated automatically by the timer, etc.
•
Display Only Power ON
Power On operated when the button of Remocon : TIMER/CLOCK ADJ. button is pressed during standby.
Power On operated only after various setting or checking of timer setting.
*
Power On is disabled for about 3 seconds after Power OFF.
2
Power ON timing chart (PDC125A Power ON sequence)
Normal Power ON
STEP
Internal
function
Elapsed time
(Time elapsed
after start of
Power ON)
Contents of Control
Major control terminal
STEP0 sy_ponlowp
0ms
Start of Power ON
SYSPOW(41P) L
→
H
STEP1
sy_pon1
60ms
STEP2
sy_pon2
90ms
Start of power supply to LCD driver, etc.
Start of power supply to DVD in DVD function
SYSPOW2(92P) L
→
H
DVD ON/OFF(1P) L
→
H
STEP3
sy_pon3
240ms
Start of data transfer of FUNCTION IC
initialization
Start of data transfer of LCD driver
Start of SEL_DATA(47P) communication control
Start of SEL_CLK(48P) communication control
Start of LCDDAT(26P) communication control
Start of LCDCS(27P) communication control
Start of LCDCLK(28P) communication control
310ms
Start of communication control in TX function
Start of TXCE(57P) communication control
Start of TXCLK(61P) communication control
Start of TXIDATA(66P) communication control
Start of TXODATA(62P) communication control
450ms
Cancel of DVD Reset
XDVDRST(93P) L
→
H
STEP4
sy_pon4
570ms
Start of BUS communication
Start of SDATA(23P) communication control
Start of MDATA(24P) communication control
Start of SCLK(25P) communication control
Start of SYSCS1(30P) communication control
600ms
Start of LCD display
Start of data transfer of VOLUME IC
initialization
Start of VOLCLK(46P) communication control
Start of VOLDATA/CE (45P) communication
control
XLCDRST(36P) L
→
H
STEP5
sy_pon5
1590ms
STEP6
sy_pon6
1980ms
STEP7
sy_pon7
2100ms
STEP8
sy_pon8
2130ms
Cancel of Rejection of all buttons
XHPMUTE(31P) L
→
H
5080ms
Cancel of Mute
XSYSMUTE(38P) L
→
H
XHPMUTE2(33P) L
→
H
Содержание XV-HA5
Страница 15: ...XV HA5 15 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 21: ...XV HA5 21 5 6 7 8 5 6 7 8 C D F A B E MT1389FE C2 L R CY B Cb G Y C V S_C S_Y D B 1 2 B 1 2 DVDM ASSY AWM7966 ...
Страница 22: ...XV HA5 22 1 2 3 4 1 2 3 4 C D F A B E 3 4 DVDM ASSY 2 2 A B 2 2 B 2 2 DVDM ASSY AWM7966 D ...
Страница 38: ...XV HA5 38 1 2 3 4 1 2 3 4 C D F A B E ...
Страница 85: ...XV HA5 85 5 6 7 8 5 6 7 8 C D F A B E ...