22
XV-BD422B
1
2
3
4
A
B
C
D
E
F
1
2
3
4
Case of replacing to a New LOADER Assy
After connecting LOADER Assy and MAIN BOARD Assy with FFC, please remove solder at protection point to the arrow-mark
direction by using soldering iron with your right-hand while holding the pick-up portion with your left-hand.
(Photo shows the situation after the removal of solder.)
Protection point
When the tray cannot be opened because the power cannot be turned on, it can be opened using the emergency disc
ejection rod (GGF1529). (A long, thin rod about 1 mm in diameter can be used in place of the rod.)
Insert emergency disc ejection rod (GGF1529) into the side located at the chassis, and slide the loading rack in the
LOADER Assy in the direction of the arrow, as indicated in the photo.
If the tray pops out a little, fully pull it out by hand.
How to open the tray when the power cannot be on
LOADER Assy
LOADER Assy
Emergency disc ejection rod
(GGF1529)
Emergency disc ejection rod
(GGF1529)
Loading rack
Tray open
Note:
The Emergency disc ejection rod will not reach
the Loading rack unless it is inserted in slant
upward
direction.