70
XR-VS90SW, XR-VS90, XR-VS70SW, XR-VS70
6.2.2 For XR-VS70SW and XR-VS70
1. Tape Speed Adjustment
Mechanical Adjustment
Electrical Adjustment
Check the following before starting.
• Adjustment points and test points are shown in Fig. 10, Fig. 12 and Fig. 13.
• Test tape : NCT-111 (3kHz, 30min).
No.
Mode
Test Tape
Adjusting
Points
Measurement
Points
Adjustment Procedure
Remarks
1
Deck
Ι
PLAY
NCT-111
(Playback : 3kHz)
ADJ. VR on
CASSETTE
MECHA
(Fig. 10)
TAPE TEST
POINT (Rch)
(AF Assy)
Press the PLAY SW and adjust so that the reading
becomes 3000Hz
±
20Hz. Confirm that wow & flutter
level is below 0.3% (in the reverse direction, confirm
that the reading is within 3000Hz
±
60Hz).
Front Side
AF Assy
Fig. 10 Tape Speed ADJ. Point
Cassette
Mechanism
Section
(Side View)
Tape Speed
ADJ. VR
(1) Confirm that the tape speed adjustment has been completed.
(2) Clean the heads and demagnetize them using a head eraser.
(3) Set the measurement level to 0 dBV = 1 Vrms.
(4) Use the specified tape for adjustment. Use the labeled (A)
side of the test tape.
STD-331E : For playback check
STD-632 : Normal blank tape
(5) Provide yourself with the following measuring devides:
• AC voltmeter (Noisemeter : filter off)
• AC millivoltmeter
• Low-frequency oscillator
• Attenuator
• Oscilloscope
(6) Adjust both right and left channels unless otherwise specified.
(7) Warm up the unit for several minutes before adjustment.
In particular, be sure to warm up the unit in the REC/PLAY
mode for 3 to 5 minutes before starting recording/playback
frequency characteristics adjustment.
(8) Always follow the indicated adjustment order.
Otherwise, a complete adjustment may not be achieved.
Playback Adjustment (Decks
Ι
and
ΙΙ
)
(1) Head Azimuth Adjustment
Recording Adjustment (Deck
ΙΙ
)
(1) Bias Oscillation Frequency Adjustment
(2) Recording Bias Adjustment
∗
As the reference recording level is 250nwb/m for STD-331E,
the recording level will be higher by 4 dB for STD-331B
(160nwb/m). When adjusting, pay carefull attention to the type
of tape used.
0 dB
–20
dB
30s
0 dB: 315 Hz, 250 nwb/m
315Hz
6.3kHz
10kHz
315Hz
14kHz
12.5
kHz
6.3
kHz
500
Hz
250
Hz
125
Hz
10kHz 8kHz
4kHz 2kHz
63Hz 40Hz
1kHz
30s 30s 30s 10s 10s ......................................................................................................... 10s
Fig. 11 STD-331E Test Tape
Содержание XR-VS200
Страница 23: ...19 XR VS90SW XR VS90 XR VS70SW XR VS70 34 106 85 28 29 30 87 31 70 35 107 37 43 36 33 32 25 68 69 27 ...
Страница 25: ...21 XR VS90SW XR VS90 XR VS70SW XR VS70 ...
Страница 29: ...XR VS90SW XR VS90 XR VS70SW XR VS70 25 A B C D 5 6 7 8 5 6 7 8 CN3051 F 2 3 AF AMP REGULATOR AF AMP AA ...
Страница 34: ...XR VS90SW XR VS90 XR VS70SW XR VS70 30 A B C D 1 2 3 4 1 2 3 4 PEB001A 2 2 B 3 5 M SERVO VCD ASSY 2 2 ...
Страница 55: ...XR VS90SW XR VS90 XR VS70SW XR VS70 51 A B C D 1 2 3 4 1 2 3 4 PRIMARY ASSY H XNP3026 C SIDE B H ...