3
repairing.
The products 2P and higher are mainly developed for two generations.
The 1
st
generation (VP1) applies NEC 180° sine wave plan and indoor control.
The 2
nd
generation (VP2) applies TI DSP 180° sine wave plan and outdoor control. (Exclusive of
2P unit).
There are derivative models, e.g. full DC inverter unit, inverter floor-standing unit and LC plan.
See Appendix 1 for details.
2. Wiring of Inverter AC Unit
3. Current Flow
Power
supply
Liv
e
N
eutral
Gr
ound
Live
Neutral
Communicati
on wire
Ground
Main
control
board
Indoor
unit
Outdoor
power
source
Live
Neutral
Outdoor
Unit
PFC board
IPM board
Compressor
Transformer
Display circuit
board
Motor
protector
Fan Motor
Room temperature
sensor
Coil temperature
sensor
Main control
board
Relay
Guide louver
motor
Y/G
Br
Or
BL
BL
BR
Indoor unit
Y/G
Heat exchanger
Wh
BL
Br
Y/G
Or
BL
Y/G
4-way Valve
BL
Electric
Heater
Solenoid
valve
Optional
Y/G
Outdoor unit
Fan
motor
Or
BL
Re
BL
Note: There is no LOW FAN for single-speed motor P9-2
Br
BL
Re
BL
Outdoor po
wer sou
rce
boar
d
BL
Re
Re
Re
Reactor
Compressor
Re Wh BL
Module board
Compressor top protection switch
(Optional)
Exhaust temperature sensor
Outdoor temperature sensor
Outdoor coil temperature sensor
Port: P9 pair port for dual-speed motor