24
(13) Display P1
Symptom Display
P1
Cause
Overvoltage / undervoltage protection
S/N
Inspections
How to Solve
Remarks
1
Test the supply voltage if it is
between 160V
~
260V
(
AC
)
.
It is normal protection if
exceeding this range.
2
Test if the voltage between L and N
terminal of outdoor unit is within
160V
~
260V
(
AC
)
.
It is normal protection if
exceeding this range.
Photo 24
3
If the voltage is normal:
Replace the outdoor power
source board
(14) Display P2
Symptom Display
P2
Cause Overcurrent
protection
S/N
Inspections
How to Solve
Remarks
1
Check if the outdoor fan motor is
stopped due to overheat protection,
or damaged, and if the fan capacitor
is damaged.
Replace the damaged capacitor
and the damaged outdoor fan
motor.
2
power source board or intelligent
power module damaged
VP1-- Replace the power source
board
V1-- Replace the intelligent
power module.
V4 and VP2-- Replace the
intelligent power module.