Calibrating the sensors (zero point calibration)
Checking the Zero Point
1. Position the crank arm so
it is perpendicular to the
ground, pointing downward.
2. Select [Calibration] in the
main menu of SGX-CA600.
3. Confirm the value in [Status].
Make sure that the [Tangential Line]
and [Normal Line] values are as
shown here.
•
Tangential Line: 0 ± 3 N
•
Normal Line: 0 ± 3 N
Calibration method in
power meter mode using a
cyclocomputer from another
manufacturer
For how to calibrate, refer to the User’s
Manual of the cyclocomputer you are
using.