background image

1

CONTENTS

2

Model

Rated Voltage

8m (25 Feet) 

3.0V (Dry batteries R03/LR03×2) (2 x AAA)

RG57A6/BGEFU1

Remote Controller Layout and Specifications

Environment

Signal Receiving 

Range

MODE

FAN

TEMP

SLEEP  

SWING   DIRECT

FOLLOW

      ME

  SELF 

CLEAN

ON/OFF

SILENCE

      FP

TIMER

    ON

TIMER

   OFF

2

3

6

7

7

7

8

9

12

Handling the Remote Controller ...................................................

Remote Controller Layout ..............................................................

Operational Buttons .......................................................................

Indicators on LCD Screen..............................................................

How to Use the Buttons ................................................................. 

Auto Operation................................................................................

Cooling/Heating/Fan operation......................................................

Dehumidifying Operation ..............................................................

Timer Operation...............................................................................

23

O

F~140

O

F

NOTE:

The layout of the functional buttons of
this remote as shown here is for the
standard model. Actual model purchased
may vary slightly from this version.
The signal output sent by this remote
controller is processed entirely by the
receiving air conditioning system. In case
any of the functions of the remote is not
available for the specific model of the
air conditioner, that function will not work.
Your product user’s manual may have
additional information on the use of the
remote controller.

TURBO

LED

Содержание RG57A6

Страница 1: ...C International Inc All rights reserved The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Read this manual carefully before operating your new air conditioning unit Make sure to save this manual for future reference MODE FAN TEMP SLEEP SWING DIRECT FOLLOW ME SELF CLEAN ON OFF SILENCE FP TIMER O...

Страница 2: ...ns Auto Operation Cooling Heating Fan operation Dehumidifying Operation Timer Operation 23O F 140O F NOTE The layout of the functional buttons of this remote as shown here is for the standard model Actual model purchased may vary slightly from this version The signal output sent by this remote controller is processed entirely by the receiving air conditioning system In case any of the functions of...

Страница 3: ...on Pressing this button each time will advance the setting time for automatically starting the system by 30 min each press up to reaching 10 0 and 60 min each press thereafter When the total set time elapses the system will start automatically To cancel the ON set time keep pressing the TIMER ON button until display shows 0 0 MODE MODE FAN TEMP SLEEP ON OFF SILENCE FP TIMER ON TIMER OFF 1 2 4 3 8 ...

Страница 4: ...d below when it is ON Not applicable to this version MODE MODE FAN TEMP SLEEP ON OFF SILENCE FP TIMER ON TIMER OFF 1 2 4 3 8 9 7 5 6 10 12 11 13 14 SWING DIRECT FOLLOW ME LED SELF CLEAN TURBO Operational Buttons LED FOLLOW ME Dual Function Button FOLLOW ME PRESS AT RIGHT EDGE Press to activate internal temperature sensor in the remote controller instead of the one inside the air conditioner to mea...

Страница 5: ... the difference between the actual ambient room temperature and the setting temperature on the remote controller 2 For the AUTO mode fan speed can not be selected Fan speed is automatically controlled in Auto Mode 3 If the Auto mode does not provide the desired comfort levels other suitable modes should be selected NOTE Dehumidifying operation MODE UP DOWN ON OFF 1 Press the button to select DRY m...

Страница 6: ...cond delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window When you select the timer operation the remote controller automatically transmits the timer signal to the indoor unit for the specified time Therefore keep the remote controller in...

Страница 7: ...r setting Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0H on the TIMER ON display 3 Press the TIMER OFF button...

Страница 8: ...h the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...

Отзывы: