7. PANEL FACILITIES AND SPECIFICATIONS

POWER switch

Provides electrical power to the unit.

DIGITAL IN switch

Use to select which of the DIGITAL IN terminals to use
(either COAXIAL or OPTICAL).

DEMODULATE indicator

When lighted, indicates that the input signal supplied to
the Dolby Digital (AC-3) RF IN terminal is being
demodulated.

PANEL FACILITIES

Accessories

Power cord

General

Power requirements .................................. AC 220-230 V, 50/60 Hz
Power conpsumption ................................................................. 6 W
Weight .................................................................................... 1.1 kg
Dimentions ..................................... 202 (W) 

×

 194 (D) 

×

 50 (H) mm

Accessories

 Operating instructions ................................................................. 1

 Power cord ................................................................................. 1

NOTE:
Specifications and design are subject to possible modification without
notice.

SPECIFICATIONS

(ADG1127)

1

2

3

1

2

3

"Dolby", "Digital (AC-3)" and the double-D symbol are
trademarks of Dolby Laboratories Licensing Corporation.

6. ADJUSTMENT

There is no information to be shown in this chapter.

Содержание RFD-1

Страница 1: ...TE LTD 253 Alexandra Road 04 01 Singapore 159936 PIONEER ELECTRONIC CORPORATION 1999 RRV2125 T ZZY APR 1999 Printed in Japan RF DEMODULATOR RFD 1 CONTENTS 1 SAFETY INFORMATION 2 2 EXPLODED VIEWS AND PARTS LIST 3 3 BLOCK DIAGRAM AND SCHEMATIC DIAGRAM 6 4 PCB CONNECTION DIAGRAM 10 5 PCB PARTS LIST 13 6 ADJUSTMENT 14 7 PANEL FACILITIES AND SPECIFICATIONS 14 THIS MANUAL IS APPLICABLE TO THE FOLLOWING ...

Страница 2: ...chanical parts in the appliance have special safety related characteristics These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage wattage etc Replacement parts which have these special safety characteristics are identified in this Service Manual Electrical components having such features ...

Страница 3: ...S LIST Mark No Description Part No 2 EXPLODED VIEWS and PARTS LIST NOTES Parts marked by NSP are generally unavailable because they are not in our Master Spare Parts List The mark found on some component parts indicates the importance of the safety factor of the part Therefore when replacing be sure to use parts of identical designation Screws adjacent to mark on the product are used for disassemb...

Страница 4: ...4 RFD 1 2 2 EXTERIOR 23 26 17 26 32 5 4 8 27 2 16 7 27 18 15 11 12 15 14 14 3 6 26 26 26 33 26 26 20 13 26 28 19 1 22 21 10 26 29 29 9 ...

Страница 5: ...ront Stay DND1140 11 Locking Card Spacer ONK1035 12 Disc Guard PNM1245 13 Guide Ring VEC 151 14 Washer VEC1254 15 Poron Leg VEC1987 16 Sheet B PVC VEC1990 17 Bonnet Case VNA1952 NSP 18 Main Chassis ANA7084 19 SW Stay VNE2148 20 Power Knob VAC1030 21 Cushion AEC7225 22 Front Panel Assy AXA7072 23 Caution Label ARW7036 24 25 26 Screw BBZ30P060FZK 27 Screw BBZ30P080FCC 28 Screw PMA30P060FMC NSP 29 Co...

Страница 6: ...2SC2412K Q4 2SC2412K Q2 2SC2412K Q3 2SA1037K Q6 2SA1037K IC3 2 2 MC14577CF IC4 1 2 BA4560F IC4 2 2 BA4560F CN1 JA3 COAXIAL IN JA2 OPTICAL IN D203 D206 POWER TRANSFORMER S1 FU1 VTT1153 LM2940CT 5 0 IC200 IC201 NJM79L05 V 5V V 5V VCXO 18 432MHz 6 4 5 1 2 3 1 2 IC5 1 6 2 6 TC74HCU04AF 1 2 3 4 14 2 3 1 8 6 5 7 2 3 1 8 6 5 7 1 2 1 2 AC220 230V A DEM ASSY C SW ASSY CN2 CN3 CN4 RF Signal Route 3 BLOCK DI...

Страница 7: ...UT C9M Demodulation SYNC Detection Protection 46 08MHz Oscillator Phase Comparator 1 2048 Divider 1 2 46 08MHz 9 216MHz SW S P 9kHz Timing Generator Error Correction Address Generator DAI Controller Serial Data AC 3 Synchronism D4 Q A1 DOUTB Q 82 86 83 88 89 63 55 56 79 3 4 A0 A14 D1 D7 42 36 66 1 2 1 3 4 2 1 3 4 13 10 IC7 4 4 TC74HC08AF 11 12 13 IC8 1 2 TC74HC32AF 3 2 1 9 8 4 6 5 4 70 90 IC6 1 6 ...

Страница 8: ...RFD 1 8 A B C D 1 2 3 4 1 2 3 4 AC POWER CORD AC220 230V 50 60Hz ADG1127 70mVp p AC MODE 2 5V p p BA4560F BA4560F HM62256BLFP 8T A 3 2 DEM LED and SW ASSYS ...

Страница 9: ... SW ASSY VWR1303 B LED ASSY VWY1048 POWER TRANS FORMER VTT1153 C208 220 10 AKP7037 FU1 T250mA 250V AEK1048 5Vp p 160nS 200mV p p RF Signal Route SWITCHES SW ASSY S1 POWER ON OFF LEDB ASSY S2 DIGITAL IN OPTICAL COAXIAL NOTE FOR FUSE REPLACEMENT FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE WITH SAME TYPE AND RATINGS ONLY CAUTION CAPACITOR COVER VEC 063 ...

Страница 10: ... the main parts of PCB and schematic diagrams is shown below 3 The parts mounted on this PCB include all necessary parts for several destination For further information for respective destinations be sure to check with the schematic diagram 4 Viewpoint of PCB diagrams Symbol in PCB Diagrams Symbol in Schematic Diagrams Part Name Transistor Transistor with resistor Field effect transistor Resistor ...

Страница 11: ...RFD 1 11 A B C D 1 2 3 4 1 2 3 4 DEM ASSY A VNP1649 C SIDE B A ...

Страница 12: ...RFD 1 12 A B C D 1 2 3 4 1 2 3 4 4 2 SW ASSY and LED ASSY SIDE B SIDE A B C LED ASSY B SW ASSY C CN6 A CN4 A VNP1649 C AC INLET LIVE NEUTRAL LED ASSY B SW ASSY C VNP1649 C ...

Страница 13: ... BPF ATF7001 F100 F116 CHIP BEAD DTF1070 L1 LAU680J L2 PULSE TRANS PTL1003 F2 F4 EMI FILTER VTH1012 L4 LINE FILTER VTL 004 CAPACITORS C200 C212 0 01µF AC250V ACG7020 C107 C25 CCSQCH101J50 C17 CCSQCH180J50 C3 CCSQCH750J50 C108 C109 C19 CCSQSL102J50 C12 CEANP470M10 C22 CEAT100M50 C205 CEAT102M25 C209 C42 C44 CEAT221M6R3 C112 CEAT330M16 C101 C110 C113 C116 C117 CEAT470M10 C120 C14 C23 C48 C50 CEAT470...

Страница 14: ... is being demodulated PANEL FACILITIES Accessories Power cord General Power requirements AC 220 230 V 50 60 Hz Power conpsumption 6 W Weight 1 1 kg Dimentions 202 W 194 D 50 H mm Accessories Operating instructions 1 Power cord 1 NOTE Specifications and design are subject to possible modification without notice SPECIFICATIONS ADG1127 1 2 3 1 2 3 Dolby Digital AC 3 and the double D symbol are tradem...

Отзывы: