20
RS-232C Adjustment
9) <QAP> Obtaining machine name
Sequence
Data Content
Size
Remarks
1
STX
1 Byte
02hex
2
Command echo-back
3 Byte
QAP (fixed)
3
Machine name information
18 Byte
42 inch:
A (North America model): PDP-427CMX********
G (Europe-general model): PDP-42MXE20*******
50 inch:
J (Japan model): PDP-507CMX-JP*****
A (North America model): PDP-507CMX********
G (Europe-general/CKD model): PDP-50MXE20*******
GS (Europe-general/silver model): PDP-50MXE20*******
4
Check sum
2 Byte
5
ETX
1 Byte
03hex
7) <QSU> obtaining the audio status
Sequence
Data Content
Size
Remarks
1
STX
1 Byte
02hex
2
Command echo-back
3 Byte
QSU (fixed)
3
Main volume
3 Byte
000 to 042
4
Audio mute status
1 Byte
0: OFF
1: ON
5
INPUT1 sub volume
3 Byte
000 to 020
6
INPUT2 sub volume
3 Byte
000 to 020
7
INPUT3 sub volume
3 Byte
000 to 020
8
INPUT4 sub volume
3 Byte
000 to 020
9
INPUT5 sub volume
3 Byte
000 to 020
10
Check sum
2 Byte
11
ETX
1 Byte
03hex
8) <QCI> Obtaining time information
Sequence
Data Content
Size
Remarks
1
STX
1 Byte
02hex
2
Command echo-back
3 Byte
QCI (fixed)
3
Time information
2 Byte
Hour (24 hour system) 00 to 23 Note 1)
2 Byte
Minute 00 to 59 Note 1)
2 Byte
Second 00 to 59 Note 1)
4
Dummy data
8 Byte
5
Day of week
1 Byte
1: Sunday
2: Monday
3: Tuesday
4: Wednesday
5: Thursday 6: Friday
7: Saturday
Note 1)
6
Check sum
2 Byte
7
ETX
1 Byte
03hex
Note 1) During standby and when this command was initially set, the value at the time that power was finally shut off is transmitted.