12
PLX-1000
1
2
3
4
A
B
C
D
E
F
1
2
3
4
5. DIAGNOSIS
5.1 TROUBLESHOOTING
Yes
N
o
Securely plug in the Power cord.
The unit is not turned O
N
.
Is the Power cord
securely plugged in?
The specified rotation speed
cannot be changed.
The proper voltage (3.3
V
) may not
be output from IC309 on the MAI
N
PCB Assy.
Check that there is proper
conduction between the plane
of IC309 on the MAI
N
PCB Assy
and G
N
D.
N
o LEDs light nor do keys work
even after the PO
W
ER switch is
turned.
N
o Switch the voltage selector
properly.
If voltage ranging from 110 to 120
V
is input
with the voltage selector set to 220-240
V
,
the turntable cannot rotate, even though all
LEDs on the panel are dimly lit.
* This problem actually occurred
with a sample product.
The turntable does not rotate, even
though the unit is turned O
N
.
Is the voltage selector
properly switched?
N
o
Remove any foreign matter.
Is there any foreign
matter between the
turntable and motor?
N
o
Remove any foreign matter.
Is there any foreign
matter between the
turntable and motor?
Yes
N
o
Yes
Replace the PO
W
ER switch.
Does the PO
W
ER switch
(S
W
201) on the
PLAY PCB Assy work?
Yes
N
o
Securely connect them.
Are C
N
901 and C
N
103 on
the D.D. MOTOR Assy
securely connected?
Yes
N
o
Yes
N
o
Replace the switch.
Does the PL/ST switch
(S
W
202) on the
PLAY PCB Assy work?
Yes
N
o
Replace the faulty switches.
Do the tact switches
(S
W
203/204) on the
SPEED PCB Assy work?
Yes
N
o
The command is not input to the
CPU. Replace the MAI
N
PCB Assy
then the SPEED PCB Assy,
in that order.
Do the strobe patterns change
after the TEMPO RESET button
is set to O
N
then the [33]
or [45] button is pressed?
Yes
N
o The LED is in failure. Replace the
LED (D203/204) on the SPEED
PCB Assy or SPEED PCB Assy.
Does the [33] or [45] button
LED light or go dark when
the corresponding button
is pressed?
Yes
Yes
N
o The control system is in failure.
Replace the MAI
N
PCB Assy.
Does the START/STOP
button LED light when the
button is pressed?
Yes
Yes
N
o
The circuitry may have been
shorted out. Replace the
D.D. MOTOR Assy then the
MAI
N
PCB Assy, in that order.
Are the chip fuses (P03/05/06/07)
on the D.D. MOTOR Assy
intact (not blown)?
Yes
The circuitry may have been
shorted out. Replace the
D.D. MOTOR Assy then the
MAI
N
PCB Assy, in that order.
Some part may be in failure.
Replace the AC&PLAY PCB Assy, transformer, D.D. MOTOR Assy, then the
MAI
N
PCB Assy, in that order.
The motor or the control system may be in failure.
Replace the D.D. MOTOR Assy then the MAI
N
PCB Assy, in that order.
The motor may be in failure.
Replace the D.D. MOTOR Assy.
Is the chip fuse (P04) on
the D.D. MOTOR Assy intact
(not blown)?
N
o The circuitry may have been
shorted out. Replace the
AC&PLAY PCB Assy.
Is the fuse (FU01) on
the AC PCB Assy intact
(not blown)?
[1] Abnormality regarding startup
Содержание PLX-1000
Страница 23: ...23 PLX 1000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 33: ...33 PLX 1000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 35: ...35 PLX 1000 5 6 7 8 5 6 7 8 A B C D E F A N PCB ASSY SIDE A ...
Страница 39: ...39 PLX 1000 5 6 7 8 5 6 7 8 A B C D E F D E E PHONO PCB ASSY SIDE A TRANS CN901 CARTRIDGE IC904 IC903 1 2 ...
Страница 40: ...40 PLX 1000 1 2 3 4 A B C D E F 1 2 3 4 D E E PHONO PCB ASSY SIDE B CN901 ...
Страница 41: ...41 PLX 1000 5 6 7 8 5 6 7 8 A B C D E F D D D D MOTOR ASSY SENSOR PCB SIDE B CN103 CW102 ...