The wall or ceiling structure must be capable of supporting at least five (5) times the weight of plasma display. 

If not, the wall or ceiling must be reinforced. Proper installation procedure by qualified personnel as outlined in the installations instructions 

must be adhered to. Failure to do so could result in serious personal injury

 

The entire installation instructions should be fully read and understood, including all of the safety symbols and safety precautions, before 

beginning installation.  The installation instructions should be read, understood and followed to prevent personal injury or property damage. 

Keep these installation instructions in an easily accessible location for future reference. 

Indicates that the power plug is to be disconnected from 

the power outlet. 

Safety precautions must be taken at all times. 

Contact Premier Mounts for any questions 

Warning and caution in general 

A secured structure wooden stud wall must always support the weight or load of the plasma.  Always conform the center of the wood 
stud before beginning the installation.  

Do not install in locations where there is vibration, movement or danger of impact.  Failure to do so could result in plasma cracking or 
falling from the wall causing damage and injury.  

Do not install near heater, fireplace, direct sunlight or air conditioning or any other source of direct heat energy.  Failure to do so may 
result in damage to the plasma television and could cause a risk of fire.  

At least two qualified people should always perform the installation work.  Injury and damage can result from dropping or mishandling 
the plasma television.  

Mounting structure recommended wood studs, solid-flat concrete, and reinforced metal studs. If installing the mount on other than 
wood studs use (commercially available) suitable hardware.  

Safety & Precautions  

WARNING

: Safety precaution measures must be practiced at all times during the installation of this product. Use proper safety gear and tools for the 

installations procedure to prevent personal injury or damage to the plasma displays or plasma mounts. 

Содержание PDWB-5003

Страница 1: ...PLASMA DISPLAY MOUNT MODEL INSTALLATION MANUAL VISIT US AT WWW PREMIERMOUNTS COM 3130 E Miraloma Ave Anaheim CA 92806 Phone 800 368 9700 Fax 800 832 4888 For service and parts contact ...

Страница 2: ...fety precautions o Mount diagrams o Parts List o Optional Adapters o Installing the mounting bracket o Installing the mount o Electrical o Securing the mount o Checking for proper safety and security Contents ...

Страница 3: ...all must always support the weight or load of the plasma Always conform the center of the wood stud before beginning the installation Do not install in locations where there is vibration movement or danger of impact Failure to do so could result in plasma cracking or falling from the wall causing damage and injury Do not install near heater fireplace direct sunlight or air conditioning or any othe...

Страница 4: ...UNT MOUNTING BRACKET PART PDB UWFB MATERIAL 12 GA CRS COLOR Black powder coat A Lag bolt access slot B Mounting points 4 5 used on installations other than wall mounting C Access hole for power or cables D M6 security screw mounting points used on installations other than flat wall mounting PART Mounting bracket MATERIAL 12 GA P O COLOR Black Powder coat Mount Diagrams ...

Страница 5: ...ceiling adapter adjustable range 24 to 46 QTY SIZE DESCRIPTION 4 5 16 Dia Lag bolts flat washers 1 Mounting bracket 1 PDB UWFB back plate 2 M6 x 12 mm Phillip security screws Used for additional security on mobile carts floor stands and ceiling mounts 1 Installations instructions 6 M8 x 20 Phillip screws Mount hardware Parts List TOOLS SUPPLY NEEDED CEILING ADAPTERS OPTIONAL HARDWARE LIST PSA 1 He...

Страница 6: ...back of the plasma display align the mounting holes from the mounting bracket to the holes on the plasma display Arrow found on the mount must always be pointing to the top of the plasma display before securing it to the plasma display Loosely install the six 6 M8 x 20 Phillip screws to the plasma then secure the screws with a Phillips screwdriver CAUTION Do not over tighten the M8 x 20 Phillips s...

Страница 7: ...ll using a commercially available stud finder and mark the center of the studs when found Set the mounting bracket to the wall and mark the desired height by marking the center of the Flat back plate See fig 3 Wall structure Wood studs behind the wall structure Stud centers marking Universal flat mount Adjusting the mount Desired height marking Installing the mounts CENTER OF VIEWING HEIGHT ...

Страница 8: ...opening into the 1 4 pilot hole Confirm that the wall mount is still leveled and then screw a lag bolt to the upper right side slot opening into the 1 4 pilot hole Then install the remaining two lag bolts tightly into the wall studs in the lower left and right slot openings on the wall mount Lateral movement of approximately 1 for final positioning is now possible Make any positioning changes then...

Страница 9: ...ogether Make sure all 4 tab openings are interlocked with the receiving tabs before letting go of the plasma See fig 5 Plasma display Mounting bracket Flat back plate 4 Securing tabs 4 Tab openings Wall structure Plasma display Wall structure Align all four 4 tab openings to the flat back plate receiving tabs and push the plasma as shown on arrows to lock in place Caution The plasma display is hea...