Fig. High Voltage Generating Point (Rear view)
: Part is the High Voltage Generating Points
other than the Charged Section.
60 Y DRIVE Assy
60 X DRIVE Assy
Conductive plate X
POWER SUPPLY Unit
607 SCAN A Assy
AC inlet
Power switch (S1)
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of the
non-charged section while connecting the set directly to the
commercial AC power supply. Therefore, be sure to connect the
set via an insulated transformer and supply the current.
1. Power cord
2. AC inlet
3. Power switch (S1)
4. Fuse (In the POWER SUPPLY Unit)
5. STB transformer and Converter transformer
(In the POWER SUPPLY Unit)
6. Other primary side of the POWER SUPPLY Unit
: Part is Charged Section.
607 SCAN B Assy
Charged Section
The places where voltage is 100 V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
The VSUS voltage remains for several minutes after the power to
the unit is turned off. These places must not be touched until
about 10 minutes after the power is turned off, or it is confirmed
with a tester that there is no residual VSUS voltage.
If the procedures described in “10.3 POWER ON/OFF FUNC-
-TION FOR THE LARGE-SIGNAL SYSTEM” are performed
before the power is turned off, the voltage will be discharged in
about 30 seconds.
POWER SUPPLY Unit........................................................(205 V)
60 X DRIVE Assy...............................................(–180 V to 205 V)
60 Y DRIVE Assy...............................................................(500 V)
607 SCAN A Assy...............................................................(500 V)
607 SCAN B Assy...............................................................(500 V)
High Voltage Generating Point
Содержание PDP-6070PU
Страница 46: ...PDP 6071PU 46 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Страница 47: ...PDP 6071PU 47 5 6 7 8 5 6 7 8 C D F A B E Note 1 Note 1 ADD1446 KUCXC only ADD1470 KUC and Regular only Note 1 ...
Страница 52: ...PDP 6071PU 52 1 2 3 4 1 2 3 4 C D F A B E 4 6 60 X DRIVE ASSY 60 X DRIVE ASSY ...
Страница 53: ...PDP 6071PU 53 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Страница 54: ...PDP 6071PU 54 1 2 3 4 1 2 3 4 C D F A B E 4 7 60 Y DRIVE ASSY 60 Y DRIVE ASSY ...
Страница 205: ...PDP 6071PU 205 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT MAIN ASSY IC4701 AV SW ...
Страница 206: ...PDP 6071PU 206 1 2 3 4 1 2 3 4 C D F A B E Block Diagram R2S11001FT MAIN ASSY IC4901 Component SW IC ...