9. LIST OF RS-232C COMMANDS
9.1 RS-232C COMMANDS OUTLINE
9.1.1 PREPARED TOOLS
9.1.2 USING RS-232C COMMANDS
It is necessary to prepare the following tools to use RS-232C command.
• PC
• Application for control
• 232C cable (straight)
*
It is not likely to operate correctly in Win98 function/ ME and Win for foreign countries.
*
The setting of the Com port cannot be communicated if it has not been done correctly.
(Please follow a operating instructions of the PC about the Com port.)
How to switch SR+/RS-232C ?
There are "How to switch SR+/RS-232C by remote control in Standby Mode" and "How to switch
SR+/RS-232C by remote control in the INTEGRATOR MENU" as a Method
To select SR+/RS-232C by remote control in Standby Mode
#During Standby mode, the following operation is done within 10 seconds.
To select from SR+ to RS-232C/To select from RS-232C to SR+)
During standby mode, hold the [
(or-)
] key on the remote control unit pressed
for 3-10 seconds. Then within 3 seconds after the key is released, hold the [
2-screen
] key
released, use the [
SET(ENTER)
] key on the remote control unit to set to RS-232C(the baud
rate last selected is chosen) or the [
HOME MENU
] key to set to SR+
#During IF Standby mode (once 10 seconds or more has passed after the LED goes dark during
communication), the first key press may not be accepted. In such a case, for a key operation,
first press any key other than the [
POWER
] key and [
CH
] keys, then the desired key.
#At the switch SR+/RS-232C, the LED will be blinked on the fixed time.
To select SR+/RS-232C in the INTEGRATOR MENU
#How to enter INTEGRATOR MENU.
During standby mode, press the [
Home Menu
] key, and then press the [
POWER
] key within
3 seconds. Or during Factory mode, hold the [
INTEGRATOR
] key.
#In INTEGRATOR MENU, there is a OSD where SR+(or RS-232C) is turned on/off, and it switches
on the screen.
For the PDP-4271HD/KUCXC, PDP-5071PU/KUCXC, PRO-940HD/KUCXC and PRO-1140HD/KU
CXC series Plasma Displays, the circuitry is structured as shown in the diagram below to support the
SR+ system. Controlling with either the SR+ system or RS-232C commands can be selected.
As the SR+ system is selected at shipment, to control with RS-232C commands in servicing it is
necessary to switch the paths. After servicing, be sure to return the setting to the SR+ system.
SR BLOCK
Rough diagram of switching between SR+ and RS-232C
MTB MAIN Assy
IF UCOM BLOCK
232C (DSUB_9P)
TXD (EXT), RXD (EXT)
SR_EN_B
SR+ (SR out)
232C
Driver
IC8301
(IF Microcomputer)
SR+
Interface
Содержание PDP-6070PU
Страница 46: ...PDP 6071PU 46 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Страница 47: ...PDP 6071PU 47 5 6 7 8 5 6 7 8 C D F A B E Note 1 Note 1 ADD1446 KUCXC only ADD1470 KUC and Regular only Note 1 ...
Страница 52: ...PDP 6071PU 52 1 2 3 4 1 2 3 4 C D F A B E 4 6 60 X DRIVE ASSY 60 X DRIVE ASSY ...
Страница 53: ...PDP 6071PU 53 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Страница 54: ...PDP 6071PU 54 1 2 3 4 1 2 3 4 C D F A B E 4 7 60 Y DRIVE ASSY 60 Y DRIVE ASSY ...
Страница 205: ...PDP 6071PU 205 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT MAIN ASSY IC4701 AV SW ...
Страница 206: ...PDP 6071PU 206 1 2 3 4 1 2 3 4 C D F A B E Block Diagram R2S11001FT MAIN ASSY IC4901 Component SW IC ...