PD-S507
2
1. Laser Interlock Mechanism
The position of the switch (S601) for detecting loading
state is detected by the system microprocessor, and the
design prevents laser diode oscillation when the switch
(S601) is not on CLMP terminal side (CLMP signal is OFF
or high level.). Thus, the interlock will no longer function if
the switch (S601) is deliberately set to CLMP terminal
side (low level).
The interlock also does not function in the test mode
∗
.
L a s e r d i o d e o s c i l l a t i o n w i l l c o n t i n u e , i f p i n 3 3 o f
CXA1782CQ (IC151) on the MAIN BOARD ASSY is
c o n n e c t e d t o G N D , o r p i n 2 2 o f I C 3 0 1 ( L D O N ) i s
connected to low level (ON), or else the terminals of Q151
are shorted to each other (fault condition).
2. When the cover is opened with the servo mechanism
block removed and turned over, close viewing of the
objective lens with the naked eye will cause exposure to a
Class 1 laser beam.
IMPORTANT
T H I S P I O N E E R A P P A R A T U S C O N T A I N S
LASER OF CLASS 1.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 5 mw
WAVELENGTH: 780 – 785 nm
∗
Refer to page 28.
LABEL CHECK
Additional Laser Caution
MYXK type
MVXK type
MYXK type
REAR
1. SAFETY INFORMATION
This service manual is intended for qualified service technicians; it is not meant for the casual
do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been
trained to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.