7.2 DIAGNOSIS
7.2.1 ERROR CODE DISPLAY
If a failure occurs in the Loading mechanism, the error symbol is automatically displayed on the fluorescent display screen of the front panel.
7.2.2 ERROR HISTORY AND DISPLAY
Error history display in test mode
The previously generated errors (NG processing) can be confirmed in the test mode. Since the has a backup function, the error history is
memorized even if the power is turned off. (Memory holding time : About two days)
TEST MODE: ON
TEST MODE: STOP CANCEL
Press the "BEST" button of the keys on the main body.
An error appears on the fluorescent indicator display by the above operation.
A: Disc No.
: Error code
B: Track No.
: Error sequence
C: Minute:second No.
: Error generation mode
(Only 10’s digit is valid.)
The previously generated 16 error codes (maximum) can be memorized. These error codes are displayed one at a time in the ascending order
by pressing the "BEST" button again.
Note : A product performs fail safe operation when an error occurs. At that time, an error code is memorized by the fail safe operation
after the error is eliminated.
A
B
C
A0
01
36 : 15
Short Point
W184
W188
MAIN BOARD ASSY
Short Point
W184
W188
MAIN BOARD ASSY
Focus servo : CLOSE
Short Point
W115
W102
MAIN BOARD ASSY
Short Point
W115
W102
MAIN BOARD ASSY