Water heating is another key feature of your Metro wood fi re; nearly all Metro 
models can be fi tted with a wetback, which are designed to give maximum 
output with minimal effect on the operation of the fi re. Only the Pioneer cast 
jacket wetback system should be fi tted to your Metro; alternative wetbacks 
will void the Metro’s emission approvals and may seriously affect the 
performance of the appliance and void its warranty.

If your home is in a classifi ed ‘clean air zone’, and dependent on 
requirements/restrictions which may be imposed by your local territorial 
authority (council) you may or may not be able to install a water heating 
device. If in doubt consult your local Metro retailer.

Other considerations are:

•   Distance from your Metro to the storage cylinder will affect the amount 

of hot water produced

•   Your climate & the manner in which you will ‘fi re’ your Metro will 

determine the amount of hot water produced.

Note: Wetbacks are not suitable for use in locations where the water supply 
has lime content. Lime build up inside the coil will eventually block the coil 
causing the wetback to fail.

Cost Savings

Wetbacks can enable substantial power savings, dependent on the climate 
in the area in which you live. If you live in a cold climate you are likely to use 
your Metro for many months of the year, in which case a Pioneer wetback 
will reduce or even eliminate your water heating costs over those months. If 
however you live in a warmer climate and use your Metro for only a few hours 
a day over the colder months, electricity savings will be considerably less.

Water Pressure

A common misconception is that you must have a low-pressure system 
to have a wetback; this is not true. You must have a ‘vented’ system and 
high-pressure cylinders are usually not vented. However you can install an 
‘indirect’ cylinder which contains a secondary coil inside the storage cylinder, 
enabling you to have a wetback while retaining a high-pressure system.

Wetback

Suitable for models:

Smart Booster

• Smart Insert
• LTD Smart Insert

3kW Wetback

• ECO Trend Insert (properties of 2Ha+ only)
• LTD Trend Insert

4kW Wetback

• ECO Trend Insert (properties of 2Ha+ only)
• LTD Trend Insert

Optional wetbacks

Operating your Metro fi re is simple and you will quickly learn how to get the 
best from it. First take a minute to familiarise yourself with your new Metro.

•  Raise the door handle anti-clockwise until the latch releases, and then 

slowly pull the door open. You will note that if you let the door go before 
it is at 90° to the appliance, it will fall closed. This is a safety feature 
that ensures the door cannot fall open if it is not latched securely. For 
the door to remain open, you must open it fully

•  There is a single air control making your Metro fi re easy to adjust. This 

control moves from left to right, which is ‘low to high’.

All Metro insert fi res have an air control knob located directly above and 
to the right of the door. Slide this control knob gently from right to left until 
you reach a stop, this is a preset ‘low’ position. Your Metro must not be 
operated at a lower burn rate than this pre-set low allows.

Please note: The Metro LTD Trend Insert model enables you to have total 
control of burn rate from ’high’ to ‘off’.

Safety off provision

The LTD Trend Insert model has a safety ‘off’ provision which enables 
the air control to be fully closed during fl ue pipe cleaning, and more 
importantly to enable all primary oxygen to the fi re to be cut off in the 
unlikely event of a fl ue pipe fi re. To engage the ‘off’ provision, lift the air 
control knob up and move it fully to the left.

Getting to know your Metro wood fi re

Metro Insert air control

LTD Trend Insert - Safety off provision

Содержание Metro

Страница 1: ...now your Metro 9 Operating your Metro 11 Cleaning and maintenance 11 Troubleshooting 13 Metro warranty 14 Replacement parts accessories 15 Insert Wood Fires Wood Fire Installation Owner s Operation Manual 360MM 170MM 360MM 170MM 19 Oropuriri Road New Plymouth 4312 info metrofires co nz www metrofires co nz 10 17 PIONEER MANUFACTURING LTD ...

Страница 2: ...on Mixing of appliance or flue system components from different sources or modifying the dimensional specification or components may result in hazardous conditions Where such action is considered the manufacturer should be consulted in the first instance Do not install a Metro fire if there is any sign of visible damage to the product This appliance must be regularly maintained Use authorised Metr...

Страница 3: ...t the top baffle All insert models feature a two piece top baffle which locates onto six lugs provided on the side walls of the firebox s upper chamber as detailed in Diagram 2 on page 4 The rear baffle section is 6mm folded steel and has a central locating pin fitted to its front top surface Fit this rear baffle through the door opening and into position in the upper chamber of the firebox It is ...

Страница 4: ...eposition the ashlip into its final position as illustrated in Diagram 3A taking particular attention to ensure The ashlip is the right way around Do not mark the coating on the ends of the ashlip panel as you slide it into the fascia you may need to slightly prise apart the fascia side panels as you fit the ashlip Position the bottom louvre as illustrated in Diagram 3A and refit the four screws p...

Страница 5: ...t requires an ash hearth floor protector with recommended construction of tiles on 6mm thick non combustible board The minimum floor protector projection forward of the Metro is 300mm as detailed in the table below Any non combustible material fixed directly to a combustible floor is acceptable LTD Trend Insert The LTD Trend Insert requires an insulating floor protector The forward projection is d...

Страница 6: ...ipe and secure with the 6mm bolt and nut supplied in the plastic bag 7 Refit the top baffle into the firebox s upper chamber Support by the steel plates only and keep the baffle horizontal 8 Using a suitable rated insulation fibretex 450 or similar pack any gap that exists between the sides and top of the fireplace insert cabinet and fireplace surround Do NOT block off the lower convection slots o...

Страница 7: ... firebox On the rear of the wetback casting apply the remaining contents of the tube equally around both connection pipes and also the outer circumference of the wetback which will face the inside rear wall of the firebox This will completely seal the wetback to the inside rear wall of the fire on installation 5 Fit the wetback into the firebox and position the connection pipes through the connect...

Страница 8: ...crew will thread directly into the water heater casting Repeat for the two front bolts but retain the nuts and washers 6 Remove the water heater from it s box which also contains a tube of fire cement You will note a 6mm bolt and washer is fitted to one of the casting ribs remove this 7 Smear a liberal but even amount of Pioneer fire cement over the entire flat face of the water heater in order to...

Страница 9: ... operated with cracked or broken door glass Please note the above 3 points require regular inspection maintenance every time the ash bed is cleaned out generally 3 5 times a season and if not maintained will void the firebox warranty A glowing firebox or lower fluepipe is just one sign you are over firing your appliance Please ensure you keep your proof of purchase receipt on any parts you purchas...

Страница 10: ...pressure cylinders are usually not vented However you can install an indirect cylinder which contains a secondary coil inside the storage cylinder enabling you to have a wetback while retaining a high pressure system Wetback Suitable for models Smart Booster Smart Insert LTD Smart Insert 3kW Wetback ECO Trend Insert properties of 2Ha only LTD Trend Insert 4kW Wetback ECO Trend Insert properties of...

Страница 11: ...control down lower than you need to if you want the Metro to burn overnight endeavour to obtain an 8 hour burn time not 12 hours It will take a few burns to find the correct location of your Metro s air control setting to achieve the length of burn cycle you desire as this setting is affected by several variables including fuel density flue length and outside wind velocity A smouldering fire over ...

Страница 12: ... rear edge of the baffle to drop down in front of the rear support lugs on the side of the firebox you have just removed the brick from The baffle can then be easily removed through the door opening To refit the top baffle Proceed in the reverse order and note the baffle must be fitted so its rear is touching the back of the firebox Note Cracks in the promet are not uncommon and have no adverse ef...

Страница 13: ...owl is fitted as this will increase the draw If you already have an ECO Cowl and smoke is still entering the room please add another 600mm length of flue pipe Downdraft Turbulence blockage If you have checked all of the previous factors and the fire is still smoking into the room it s possible there may be a down draft issue Down draft is environmental and can be caused by many variables and it is...

Страница 14: ...l be reduced If your Metro wood fire has been neglected by not being regularly maintained and serviced warranty may be declined It is critical the fire not be operated with over worn faulty or missing door seals Door seals will harden over time and become over worn 3 4 year s and will cause air to leak into the fire causing the appliance to over fire Do not operate the fire with cracked or broken ...

Страница 15: ...must be replaced Note Impact damage when loading wood and burning wood which is not properly seasoned i e 25 moisture content or more will cause the promet to disintegrate and require replacement Always burn dry well seasoned wood and take care when loading wood into the firebox Parts guide for your Metro Promet baffles and wetback options Model Type of promet required Type of steel baffle s requi...

Страница 16: ...r all models which is generally required when applying for a building consent See your Metro retailer to obtain a copy or visit www metrofires co nz metrofires co nz Visit the Metro website metrofires co nz to view Metro s video demos showing the latest in wood fire technology energy saving options You can view the entire Metro product range find out where your nearest Metro retailer is located or...

Отзывы: