KEX-M9527ZT/UC
A
B
C
D
1
2
3
4
1
2
3
4
44
Connection:
Setting of the pulse generator (setting of
superimposed pulse)
Adjustment:
1. Setting of SSG
Receiving frequency
: 999 kHz (KEX-M9627ZT/ES)
Percentage modulation : 30%
Receiving frequency
: 1,000 kHz (KEX-M9527ZT/UC
KEX-M9727ZT/UC)
Modulation frequency : 400 Hz
Antenna input
: 74 dBuV (EMF)
2. Tune a RADIO to the "999kHz" or "1,000kHz" with 1' condition.
3. Mix signal with the above-mentioned pulse and
SSG' moduration OFF.
4. Variable resistance adjust noise level to a
minimam.
Adjustment point : VR561
Pulse generator
(equivalent to HP8011A)
SSG
2-signal pad
AM dummy
Output
Noise meter
Pulse width :50usec
Pulse intervals :5msec
Pulse voltage :4Vp-p
4Vp-p(EMF)
50us
5ms
AM NOISE CANCELER ADJUSTMENT
KEX-M9527ZT/UC
KEX-M9727ZT/UC
KEX-M9627ZT/ES