GEX-P6400TV/UC
A
B
C
D
5
6
7
8
5
6
7
8
65
-
TV Tuner Section (NTSC)
(GEX-P6400TV/UC, GEX-P6450TV/ES)
Notes:
1. TV sensitivity: based on 75-ohm loaded (UN BAL) voltage and video carrier level
2. Audio carrier level: (Video carrier level) -6dB
3. Adjustments should be made with the ANT1 selected.
Step
Adjustment item
Input signal (input point, waveform, specs,
and other conditions)
Output signal (measuring point,
waveform, adjusting method)
Adjusting instrument
and adjusting points
Specs.
Symptoms
with poor adjustment
1
Video detection coil
adjustment
Apply the RF signal of the rated level (59dB
µ
V at 75ohms) that is
synchronized with US11ch (P carrier: 199.25MHz) and modulated
with a white signal (White 100%, audio: monaural 400Hz,
25kHz/div).
Measuring point: TP. VIDEO or through-hole marked
with
“
_
and VIDEO
”
The DC level when the rated input is applied.
DC meter
L2402
Minimum within the allowable
rotating range
Sag or ringing on
the video signal
2
AGC start adjustment
Measuring point: TP. AGC or IC2401-11pin marked
with
“
”
(1) Voltage with -20dB
µ
V input: Va
(2) Voltage with 50dB
µ
V input: Vb
strong input
DC meter
VR2401
Vb = Va -0.9V
Waveform deformed
due to video S/N
deterioration or
3
Video output level
adjustment
Measuring point: TP.TVV or Q2454 emitter
Sync tip to 100IRE (waveform top)
Oscilloscope
VR2751
1.0
±
0.1Vp-p
White luminance is
too high or too low.
4
Audio detection coil
adjustment
Measuring point: TP.REF, TP.AFC or IC2301-pin 9 and
pin 12 marked with
“
”
The DC level between the above 2 points
Center meter
L2301
0
Audio distortion
deteriorated or
attenuated
5
Soft mute adjustment
Measuring point: TP.TVMONO or through-hole
marked with
“
_
and TVMONO
”
(1) Output level with the rated input: Vc
(2) Output level with -20dB
µ
V input
Noise meter
VR2301
Vc -20
±
1dB
Audio noise changed
at the time of unlocked
tuning or at weak
electronic strength areas.
6
Audio output level
adjustment
Measuring point: TP.TVMONO or through-hole
marked with
“
_
and TVMONO
”
Output level with the rated input (reception: Hi-Z)
Noise meter
VR2303
240mVrms
Audio level is too
high or too low.
7
SD sensitivity
adjustment and
Measuring point: TP.SD or IC2301-Pin19 marked with
“
”
(1) In case of 32dB
µ
V input
confirmation
(2) In case of 37dB
µ
V and 27dB
µ
V input
DC levels
DC meter
VR2302
(1) Low to High
(2) 37dB
µ
V: H, 27dB
µ
V: L
SEEK stop sensitivity
changed
8
Diversity adjustment
Measuring point: TP.CNT, TP.VDIV5V or IC2301-Pin2
and Pin19 marked with
“
”
should be 0.5 times larger than that at TP.VDIV5V
(or Pin 19).
DC meter
TC2110
(VDIV5V / 2)
±
0.1V
Abnormal diversity
operation at weak
electronic strength
With the rated input, the voltage at TP.CNT (or Pin 2)
areas
Содержание GEX-P6400TVP
Страница 5: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 5 ...
Страница 10: ...GEX P6400TV UC A B C D 1 2 3 4 1 2 3 4 10 2 2 EXTERIOR ...
Страница 23: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 23 ...
Страница 31: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 31 ...
Страница 34: ...GEX P6400TV UC A B C D 1 2 3 4 1 2 3 4 34 A a B b B a B a B b 1 2 3 1093 RF RF RF RF RF IF IF PIF PIF SIF ...
Страница 35: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 35 A a B b B a B a B b 4 IF IF PIF PIF SIF PIF PIF SIF SIF PIF PIF ...
Страница 37: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 37 B a B b B b 4 PIF MA MA MA MA ...
Страница 40: ...GEX P6400TV UC A B C D 1 2 3 4 1 2 3 4 40 A a B b B a B a B b 1 2 3 1094 RF RF RF RF RF IF IF PIF PIF SIF ...
Страница 41: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 41 A a B b B a B a B b 4 IF IF PIF PIF SIF PIF PIF SIF SIF PIF PIF ...
Страница 43: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 43 B a B b B b 4 PIF MA MA MA MA ...
Страница 45: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 45 A A MOTHER UNIT SIDE B ...
Страница 47: ...GEX P6400TV UC A B C D 5 6 7 8 5 6 7 8 47 B B TV TUNER UNIT SIDE B AGC CNT VDIV5V TVV VIDEO TVMONO AFC REF SD ...