Detected protection history
[Purpose]
[Basic operations]
FL Display
POWER OFF
Number of detections of cord
disconnection (DC and OL DET line)
(simultaneous detections of DC and
OVERLOAD)
Number of detections of fan
abnormalities
Number of overload detections
Number of DC detections
Number of detections of abnormal
temperature
3
3
3
3
Normal display
Description of Indications
Duration
(sec.)
The numbers of detections for various protection processes are displayed.
When the keys are pressed, the numbers of DC detections, overload detections, detections of connectors
disconnection inside unit (It is detected by both DC and OVERLOAD detections.), detections of fan abnormalities,
and detections of abnormal temperature are displayed for 3 seconds each, in that order.
The maximum value of each detections is 255.
[How to enter/exit]
During Standby mode, simultaneously press and hold the DVR/VCR1 and ENTER keys for 5 seconds to enter this
mode. This mode is automatically exited when all the indications have finished.