DVR-RT602H-S
132
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Press the ESC key.
(EPG EURO)
EPG Data Receive Err Details - 1
Date : 03/31
Start Time : 13:00 END Time : 13:30
Host CH : 03 P-ON Kind : Download
Data Receive Part Total Err : 000000
Pkt Rcv Num : 001853 Pkt Snd Num : 001853
Inv Line Err : 000000
Slice Cont : Auto EQ : OFF LV : -h
Temporary Buffer Information
Pool Num : 000000 Max Store : 000000
Discard Pkt : 000000 Use Num : 000000
012345678901234567890123456789012345678901234567
0 1 2 3 4
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
[How to quit]
[Description of the Detail screens]
Press the DIG/ANA key while the Summary screen is displayed. Up to 6 detail screens (1 to 6) are
displayed, one each time the DIG/ANA key is pressed. Each detail screen 1 to 6 corresponds with the
EPG reception error logs from the top on the Summary screen.
[How to enter]
Line
Display item
Description
Remarks
2. Detail screen
Note:
The data on lines 12-14 are for software development, not for service use.
Line 01
Lines 03-05,
Reception conditions
Lines 07-10,
details on errors during
reception
EPG Data Receive
Err Details-X
Date
Start Time
END Time
Host CH
P-ON Kind
Total Err
Pkt Rcv Num
Pkt Snd Num
InvLine Err
The rightmost figure represents the
number of the current detail screen.
This number corresponds to the order
of the EPG reception error log from the
top.
: Month/day when reception started
: Time when reception started
: Time when reception ended
: Data-receiving channel
: Methods for acquiring the EPG data
(host scanning and downloading)
: Total numbers of errors during reception.
The total number of Hamming Err, Trans
Err and InvLine Err indicated on the
Detail screen. A number 999,999 or
greater is displayed as "999999."
: Total number of received packages. A number
999,999 or greater is displayed as "999999."
: Total number of packages that were sent to
the application program among all the
received packages. A number 999,999 or
greater is displayed as "999999."
Only during initialization, host scanning
is automatically executed to find the
host broadcast.
Total Errors: If the total number of errors
reaches two digits or greater, it is likely that
EPG data acquisition failed. Display
subscreen 1 of the first screen and check the
electric field intensity from the AGC level.
If the total number of received
packages is 0, it is likely that the
country and postal-code settings are
wrong.
: Total number of errors that were gene-
rated by receiving data from invalid lines.
A number 999,999 or greater is display-
ed as "999999."
Slice Cont
: Slice level control
Auto-Tu Con, Manual - Syscon.
EQ
: Equalizer setting (ON, OFF)
LV
: Slice level (10~30 hex)
(Only when the slice Cont is Manual.)