DV-79AVi
88
1
2
3
4
1
2
3
4
C
D
F
A
B
E
FL
Description of
Error
Causes if with a DVD
Causes if with a CD
Operation of the Unit
39
SGC converge
timeout
SGC could not converge during detects the peak
Open
41 Spindle timeout
The unit did not enter Stop mode within 10 seconds of issuance of a Stop command.
Disc distinction is not completed even if passes for 10 seconds after the spindle turned.
Stop
48
Spindle FG transition
timeout
Did not reach to the rotating speed that ATB was
possible for less than 10 seconds. Did not reach aim
CAV lock speed (high: 10%, low: 50%) for less than 10
seconds. CAV process passed more than 5 seconds or
abnormal speed was detected. Spindle does not lock for
less than 3 seconds in the BCA read start or end.
Stops. (FG timeout)
49
Spindle PLL
transition timeout
CAV process passed more than 5 seconds. Abnormal speed was detected.
Stops.
("73" is displayed during
starting process.)
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB.
Stops.
("73" is displayed during
starting process.)
51
Auto sequence
timeout of peak
detection
ABUSY did not return within 1 second after the DDTCT
(peak detection) command was sent.
Stop
52
Auto sequence
timeout of focus
jump down
ABUSY did not return within 30 mS after the FJMPD
(Focus jump 1 to 0) command was sent.
Open
53
Auto sequence
timeout of focus
jump up
ABUSY did not return within 30 mS after the FJMPU
(Focus jump 0 to 1) command was sent.
Open
54
Auto sequence
timeout of play AGC
ABUSY did not return within 50 mS after the GSUMON
(play-AGC-measuring) command was sent.
Stop
55
Auto sequence
timeout of disc-type-
sensing
ABUSY did not return within 2 seconds after the
DJSRT (disc-sensing) command was sent.
Stop
56
Auto sequence
timeout of ATB2
ABUSY did not return within 1 second after the
TBLOFS (Internal ATB after the completion of external
ATB) command was sent.
Stop
57
Auto sequence
timeout of tracking
servo ON
ABUSY did not return within 0.5 sec. after the TSON
(tracking servo ON) command was sent.
Stop
58
Auto sequence
timeout of ATB1
ABUSY did not return within 0.2 sec. after the TBL
(external ATB) command was sent.
Stop
59
Auto sequence
timeout of focus gain
adjustment
ABUSY did not return within 2 seconds after the FGN
(focus gain adjustment) command was sent.
Stop
5A
Auto sequence
timeout of tracking
gain adjustment
ABUSY did not return within 2 seconds after TGN
(tracking gain adjustment) command was sent.
Stop
5B
Auto sequence
timeout of offset
adjustment
ABUSY did not return within 1 second after the AVE
(offset adjustment) command was sent.
Stop
5C
Auto sequence
timeout of
modulation factor
measurement
ABUSY did not return within 200 mS after the ADJMIR
(modulation factor measurement) command was sent.
Stop
5D
Auto sequence
timeout of auto focus
bias
ABUSY did not return within 2 seconds after the AFB
(auto focus bias) command was sent.
Stop
5F
Auto sequence
already busy
A command could not be sent because ABUSY was
low. ABUSY did not return within 200 mS after TLV
command was sent.
Stop
62 Pause retry error
Pause mode could not be restored within three retries
after it had been released.
Continues operation
71
ID reading check
during playback
An ID could not be read for 1 second or more.
Stop
72
Subcode check
failure during
playback
No frame could be read for 3
seconds or more.
Stop
73
ID can not read
during startup
An ID could not be read within 1 second after the AFB
tracking on.
Opens
(ID readout failure)
Содержание DV-79AVi-s Elite
Страница 29: ...DV 79AVi 29 5 6 7 8 5 6 7 8 C D F A B E D AUDIO DIGITAL SIGNAL ROUTE D D D D A 5 6 2 6 A for FRASH ...
Страница 33: ...DV 79AVi 33 5 6 7 8 5 6 7 8 C D F A B E AUDIO DIGITAL SIGNAL ROUTE D AUDIO SIGNAL ROUTE 25 C ...
Страница 35: ...DV 79AVi 35 5 6 7 8 5 6 7 8 C D F A B E V S_C S_Y S_C S_C S_C V V V S_Y S_Y S_Y Y Cb Cr Y Cb Cr Y Cb Cr B ...
Страница 42: ...DV 79AVi 42 1 2 3 4 1 2 3 4 C D F A B E ...