29
CT-W208R
(2) Recording Bias Adjustment
• After the adjustment, caution should be exercised so as not to become under bias by checking the distortion rate.
VR401
REC/
PAUSE
1
Input a 315Hz (–26 dBV) signal to
the LINE INPUT.
L ch
R ch
VR402
–26 dBV
REC
=
PLAY
2
Load the STD–632 test tape and
record/playback the 315Hz and
10kHz signals. (see the Note below)
Repeat adjustment until playback level of
the 10kHz signal is within 0dB
±
0.5dB
from that of the 315Hz signal.
(3) Recording Level Adjustment
VR301
REC/
PAUSE
1
L ch
R ch
VR302
TP 1 (L ch)
TP 2 (R ch)
(MAIN UNIT)
Input signal level
–11.2 dBV
REC
=
PLAY
2
• STD–632 test tape and record/
playback the 315Hz signal.
• DOLBY NR : OFF
Repeat recording, playback and
adjustment until playback level of the
315Hz signal becomes –10dBV
±
0.5dB.
Note: Set the 10kHz input signal level to the same value as the 315Hz input signal level of step 1.
Input a 315Hz signal to the LINE
INPUT.
Remarks
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
Remarks
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
LINE OUT
(L, R ch)
REC
=
PLAY
1
(4) Recording Frequency Characteristics Confirmation
LINE OUT
(L, R ch)
Remarks
No.
Mode
Input Signal/Test Tape
Adjustment Points
Measurement
Points
Adjustment
Value
Check that the frequency
characteristic is within the
range of Fig. 6-4.
• STD–632, STD-622 test tape
• Record with –26.0 dBV
• DOLBY NR : ON/OFF