CDX-MG6047ZH/UC
53
5
6
7
8
5
6
7
8
C
D
F
A
B
E
[RPT]
Power Off
[1]
Focus Close/S-curve/
F, EQ Measurement
[4]
Focus Mode Select
[5]
Tracking Servo
Close
[RPT]
Power ON
(T.OFFSET adjustment required)
TRK
DSC
6
00
[TR+]
Power ON
(T.OFFSET adjustment not required)
[ASEL]
Mechanism Test Mode
Initial State
[CD]or[SOURCE]
Source CD
TRK
DSC
[RPT]
Power Off
[5]
Tracking Close
(AGC, Applicable Servo)
[4]
Tracking Close
(No AGC, Applicable Servo)
[1]
Auto Adjustment Display
/Rough Servo
[ASEL]
Tracking Balance
Adjustment
[Key]
Contents
Display
[EJECT]+Reset
Test Mode In
[1]
AGC
[4]
CRG/TR Jump Count
Select
[FF]
CRG+/TR Jump+
[REV]
CRG–/TR Jump–
[2]
SPINDLE
Uniform/
Double Switching
[RPT]
Power Off
[5]
AGC/F.BIAS
Display Switching
or
[FF]
CRG+
[REV]
CRG-
[FF]
CRG+
[REV]
CRG-
[RPT]
Power Off
[ASEL]
Trackig Open
[ASEL]
Trackig Open
*1
*6
*5
*3
*2
*2
*4
*1) Switching must take place in the following sequence.
TRK 00
TRK
(
)
99
S.Curve Check
Focus EQ Measurement.
Focus Close
*2)
→
→
→
→
→
9X(8X):91(81)
4 TR
92(82)
10 TR
93(83)
32 TR
94(84)
100 TR
95(85)
CRG Move
96(86)
*4)
→
→
→
F.AGC Gain
F.AGC Gain
F. BIAS Setting
(AGC Gain = (Current value/Initial value) x 20)
→
→
→
→
→
Single TR /4TR / 10TR / 32TR / 100TR
Single TR
*3) Switching must take place in the following sequence.
It applies to the CRB Move and 100TR Jump alone.
Min/Sec (or Track No.)
*5) Switching must take place in the following sequence.
F.Cancel Display
*6) Switching must take place in the following sequence.
T.Offset Display
T.Bal Display
Rough Servo.
(F.Bias value, F.Cancel value, T.Offset value, T.Bal value
= (Upper 8 bits of the setting (7F[H] to 80[H] + 128)/4
= 63[D] to 32[D] to 00[D]).
•
•
•
Operation of TR JUMPs other than 100TR is continued after your finger has left the key.
CRG Move and 100TR Jump are forced to the Tracking Close Mode when the key is released.
Powering on or off resets the Jump Mode to the Single TR (91).
When ACC or Back up is off, the test mode is canceled.
Note:
Note:
Note:
The H-BUS head unit must be employed for controlling the test mode.
Sound is unavailable even after the tracking has been closed
(this trouble results when the IC for the STS is not controlled in the test mode).
When you pressed the [FF] or [REV] key during the Focus Search, you must turn the power off immediately
(otherwise, the lens can stick resulting in actuator damages).
[Key]
[RPT]
[FF]
[REV]
[5]
[ASEL]
[1]
[2]
[3]
[4]
Operation
Power ON/OFF
CRG+/TR Jump+
(Toward outer perimeter)
Tracking Close/AGC gain,
F.Bias adjustment value display switching
Auto Tracking Balance adjustment/
Tracking Open
Focus Close, S.Curve, F.EQ measurement/
Rough Servo/AGC
Focus Open
Jump Off
Focus Mode select/Tracking Close/
CRG/TR Jump Switching
CRG-/TR Jump-
(Toward inner perimeter)
??
55
TRK
DSC
6
99
TRK
DSC
6
72
TRK
DSC
??
55
TRK
DSC
6
91
TRK
DSC
6
0X
TRK
DSC
6
00
TRK
DSC
6
99
TRK
DSC
6
00
or
TRK
DSC
6
99
TRK
DSC
6
00
or
TRK
DSC
6
99
TRK
DSC
??
55
TRK
DSC
??
55
TRK
DSC
6
XX
TRK
DSC
6
XX
TRK
DSC
6
??
TRK
DSC
6
XX
TRK
DSC
6
??
TRK
DSC
6
XX
TRK
DSC
6
8X
or
TRK
DSC
6
9X
TRK
DSC
6
8X
or
TRK
DSC
6
9X
TRK
DSC
6
XX
TRK
DSC
6
XX
TRK
DSC
6
XX
TRK
DSC
6
8X
or
TRK
DSC
6
9X
TRK
DSC
6
8X
TRK
DSC
6
8X
or
TRK
DSC
6
9X
TRK
DSC
??
55
TRK 01
TRK 02
[TR+]
Power ON
(T.OFFSET adjustment not required)
DSC=DISC NO.
TRK=TRACK NO.
Before starting the Servo Test mode, the currently selected DISC NO. is displayed.
During Power is ON, DISC NO. is set to 6.
r
Important: For continued key operations, keep the interval between key operations 4 seconds or more.
-
CD Player Flowchart
Содержание CDX-MG6047ZH
Страница 8: ...CDX MG6047ZH UC 8 1 2 3 4 1 2 3 4 C D F A B E 2 2 EXTERIOR ...
Страница 13: ...CDX MG6047ZH UC 13 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 18: ...CDX MG6047ZH UC 18 1 2 3 4 1 2 3 4 C D F A B E 1 2 3 A a A b A a A a A b D CN701 ...
Страница 19: ...CDX MG6047ZH UC 19 5 6 7 8 5 6 7 8 C D F A B E 4 5 6 A a A b A a A a A b B B KEYBOARD UNIT ...
Страница 20: ...CDX MG6047ZH UC 20 1 2 3 4 1 2 3 4 C D F A B E 1 2 3 A a A b A b A CONTROL UNIT ...
Страница 31: ...CDX MG6047ZH UC 31 5 6 7 8 5 6 7 8 C D F A B E A A CONTROL UNIT SIDE B 3 2 1 3 2 1 1 5 3 4 2 D CN701 B CN901 ...
Страница 33: ...CDX MG6047ZH UC 33 5 6 7 8 5 6 7 8 C D F A B E B B KEYBOARD UNIT SIDE B ...
Страница 35: ...CDX MG6047ZH UC 35 5 6 7 8 5 6 7 8 C D F A B E C C CD CORE UNIT SERVO UNIT SIDE B ...
Страница 37: ...CDX MG6047ZH UC 37 5 6 7 8 5 6 7 8 C D F A B E D D CD CORE UNIT STS UNIT SIDE B ...
Страница 38: ...CDX MG6047ZH UC 38 1 2 3 4 1 2 3 4 C D F A B E 4 5 MOTOR PCB B M M4 CARRIAGE SPINDLE MOTOR M5 E E MOTOR PCB B ...
Страница 39: ...CDX MG6047ZH UC 39 5 6 7 8 5 6 7 8 C D F A B E M 4 RRIAGE 1 12 D CN301 E ...
Страница 41: ...CDX MG6047ZH UC 41 5 6 7 8 5 6 7 8 C D F A B E 1 41 F F MOTOR PCB A SIDE B G CN801 ...
Страница 43: ...CDX MG6047ZH UC 43 5 6 7 8 5 6 7 8 C D F A B E 4 8 PCB UNIT E I I PCB UNIT E SIDE A SIDE B I PCB UNIT E ...
Страница 44: ...CDX MG6047ZH UC 44 1 2 3 4 1 2 3 4 C D F A B E 4 9 PCB UNIT C 4 1 D883 S885 MAX DETECT Q881 I J J PCB UNIT C ...
Страница 63: ...CDX MG6047ZH UC 63 5 6 7 8 5 6 7 8 C D F A B E 7 1 3 CONNECTOR FUNCTION DESCRIPTION ...
Страница 68: ...CDX MG6047ZH UC 68 1 2 3 4 1 2 3 4 C D F A B E 8 OPERATIONS CD LOADING SLOT DISC SELECT BUTTON EJECT BUTTON ...
Страница 69: ...CDX MG6047ZH UC 69 5 6 7 8 5 6 7 8 C D F A B E ...