No.
Cause
Diagnostics Point
Item to be Checked
Corrective Action
Reference
8
Signal error
SR
V
A Assy
Check that a sine-wave signal is input to
Pins 29 and 30 of IC7001.
The IC7001 may be loosely connected or defective.
Resolder them, if necessary. If the symptom persists,
replace SODC (IC7006).
9
Defective traverse
mechanism
-
If the symptom persists after the above
corrections,
Replace the parts in the order of (1) DRI
V
ER IC
(IC7001), (2) SR
V
A Assy, then (3) traverse mechanism.
N
either a CD nor a D
V
D can be played back.
No.
Cause
Diagnostics Point
Item to be Checked
Corrective Action
Reference
1
Short-circuit pad
Traverse
mechanism
Check if the LD short-circuit pad is
short-circuited.
If it is, open it.
2
LD current
SR
V
A Assy
Check that the LD current is within the
specified range.
If there is any error, replace the traverse mechanism.
5.2 Failure Judgment
of the Pickup ASSY
5.2 Failure Judgment
of the Pickup ASSY
3
Power supply
error
SR
V
A Assy
Check the power voltages (12
V
, 5
V
,
3.3
V
, 1.5
V
,
V
REF1,
V
REF2 and
V
HALF).
Check the connection of the parts at the periphery of
the power-supply IC that does not output the voltage.
If the symptom persists after a corrective action, the
power supply block is defective. Replace it.
4
I
N
SW signal
error
SR
V
A Assy
Check the I
N
SW signal. (L at O
N
.)
If the signal waveform is not proper, replace the
I
N
SW Assy.
5
MU1 signal error
SR
V
A Assy
Check that the MU1 signal becomes H
after loading is completed.
DRI
V
ER IC (IC7001) and SODC (IC7006) may
be improperly soldered or defective.
Resolder them, if necessary. If the symptom persists,
replace SODC (IC7006).
6
Improper
assembling
Traverse
mechanism
Check if the objective lens is dirty.
Clean the lens.
7
A–F signal error
SR
V
A Assy
Check the A–F signals (C
N
7001).
Check that the signals fluctuate with 2.2
V
at the center.
If a DC signal is not output, check the
V
REF1. If a DC
signal is not output from it, replace the FEP (IC7002).
If an AC signal is not output, check the soldering at the
C
N
7001–IC7002 of the pickup. If soldering is improper,
resolder it. If soldering is OK, replace the parts in the
order of (1) FEP (IC7002), (2) DRI
V
ER IC (IC7001),
(3) SODC (IC7006), (4) SR
V
A ASSY, then (5) traverse
mechanism.
8
RF signal error
SR
V
A Assy
Check the RF signal (C
N
7001).
Compare the waveform with the operational waveform
to check if its quality is low. Check if the disc is dirty or
scratched. Check the polarity of the 7/x6 signal. When it
is normal, Check the connections between pickup and
C
N
7001 and IC7002. If soldering is improper, resolder it.
If soldering is OK, replace the parts in the order of
(1) FEP (IC7002), (2) DRI
V
ER IC (IC7001), (3) SODC
(IC7006), (4) SR
V
A Assy, then (5) traverse mechanism.
9
-
If the symptom persists after the above
corrections,
Replace the parts in the order of
(1) DRI
V
ER IC (IC7001), (2) FEP (IC7002), (3) SODC
(IC7006), (4) SR
V
A Assy, then (5) traverse mechanism.
Only a CD cannot be played back
No.
Cause
Diagnostics Point
Item to be Checked
Item to be Checked
Corrective Action
Reference
1
LD current
SR
V
A Assy
Check that the LD current is within the
specified range.
If there is any error, replace the traverse mechanism.
2
7/x6 signal error
-
Check that the 7/x6 signal is H during
CD playback.
Check the connections between IC7006 and C
N
7001.
If soldering is improper, resolder it.
3
E,F signal error
SR
V
A Assy
Check the E, F signals (C
N
7001).
Check that the signals fluctuate with 2.2
V
at the center.
If a DC signal is not output, check the
V
REF1. If a DC
signal is not output from it, replace the FEP (IC7002).
If an AC signal is not output, check the soldering at the
C
N
7001–IC7002 of the pickup. If soldering is improper,
resolder it. If soldering is OK, replace the parts in the
order of (1) FEP (IC7002), (2) DRI
V
ER IC (IC7001),
(3) SODC (IC7006), (4) SR
V
A Assy, then (5) traverse
mechanism.
4
RF signal error
SR
V
A Assy
Check the RF signal (C
N
7001).
Compare the waveform with the operational waveform
to check if its quality is low. Check if the disc is dirty or
scratched. Check the polarity of the 7/x6 signal. When it
is normal, Check the connections between pickup and
C
N
7001 and IC7002. If soldering is improper, resolder it.
If soldering is OK, replace the parts in the order of
(1) FEP (IC7002), (2) DRI
V
ER IC (IC7001), (3) SODC
(IC7006), (4) SR
V
A Assy, then (5) traverse mechanism.
10.1 SR
V
A
ASSY (1/2)
5.4 Operational
Waveforms
10.1 SR
V
A
ASSY (1/2)
5.4 Operational
Waveforms
10.1 SR
V
A
ASSY (1/2)
5.4 Operational
Waveforms
Содержание CDJ-2000
Страница 10: ...10 CDJ 2000 1 2 3 4 A B C D E F 1 2 3 4 2 2 DISCS FILES PLAYABLE ...
Страница 11: ...11 CDJ 2000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 12: ...12 CDJ 2000 1 2 3 4 A B C D E F 1 2 3 4 2 3 PANEL FACILITIES ...
Страница 13: ...13 CDJ 2000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 14: ...14 CDJ 2000 1 2 3 4 A B C D E F 1 2 3 4 ...
Страница 19: ...19 CDJ 2000 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 73: ...73 CDJ 2000 5 6 7 8 5 6 7 8 A B C D E F ...