PERIODIC MAINTENANCE
1.
CLEANING THE SQUEEGEE TUBE
Periodically, or whenever suction seems to be unsatisfactory, check the squeegee tube is not
obstructed. To clean it, proceed as follows:
1. Remove the tube from the sleeve on the squeegee.
2. Remove the other end from the recovery tank.
3. Wash the inside of the tube with a water jet introduced from the side where it is
connected to the tank.
4. Re-assemble the tube.
WARNING: Do not wash the tube running between the suction
unit and the suction cap.
2.
CLEANING THE SOLUTION TANK AND FILTER
1. Detach the quick connection (1) to avoid breaking the connection itself.
2. Remove the recovery tank.
3. Loosen the solution tank cap. (2)
4. Remove the filter and clean it. (3)
5. Rinse the tank and clean with a jet of water.
6. Re-assemble the tank, carrying out the above operations in the reverse order.
7. Reassemble the filter and cap.
WARNING: Before carrying out any type of maintenance,
disconnect the machine's battery connector.
WARNING: This operation must be carried out by using gloves in
order to protect against contact with dangerous solutions.
20