Instructions for Connection to the Power Supply
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electrical shock. This product is equipped with a cord having an equipment-
grounding conductor and grounding plug. The green (or green and yellow) conductor in the cord is the grounding
wire. Never connect this wire to other than the grounding pin of the attachment plug. The plug must be inserted into
an appropriate oulet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING:
Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have
a proper outlet installed by a qualified electrician.
This product is for use on a nominal 120 volt circuit and has a grounding attachment plug that looks like the plug
illustrated in Fig. 5. Make sure that the product is connected to an outlet having the same configuration as the plug.
No adaptor should be used with this product.
WARNING:
To prevent possible electric shock, protect the machine from rain. Keep the machine in a dry
building.
WARNING:
To prevent possible electric shock, always use a 3-wire electrical system connected to the electrical
ground. For maximum protection against electrical shock, use a circuit that is protected by a ground
fault circuit interrupter. Consult your electrical contractor.
WARNING:
Do not cut, remove or break the ground pin. If the outlet does not fit the plug, consult your electrical
contractor.
WARNING:
Have worn, cut or damaged cords replaced by an authorized service person.
Extension Cords
Use only an approved extension cord with three conductors, a plug with three terminals, and a connector body with
three holes. The machine has a power cord with wire size 14 AWG (AWG means American Wire Gauge).
WARNING:
If you use an extension cord, use an extension cord with minimum wire size 12 AWG. Do not use an
extension cord longer than 50 feet. Do not join two extension cords.
Содержание FM 1700
Страница 1: ...Floor Maintainer FM1700 FM2000 Operator s Manual...
Страница 2: ......
Страница 10: ...10...
Страница 18: ...18...
Страница 28: ...120V Electrical Schematic 28 Section D Parts Manual...
Страница 29: ...230V Electrical Schematic 29 Parts Manual Section D...
Страница 30: ...Handle Assembly 30 RF062800 051916 10 12 11 1 2 3 9 4 5 8 14 7 14 7 13 7 6 Section D Parts Manual...
Страница 34: ...Main Assembly 34 RF063000 051916 5 4 8 6 8 7 17 18 19 2 1 3 16 10 9 12 11 14 13 15 Section D Parts Manual...
Страница 38: ......
Страница 39: ......