6
BALL FLOAT VACUUM SHUT-OFF
Prior to using the machine, always check that the float filter is clean and the ball can travel freely. When the
recovery tank is full, the ball float will rise and will shut off the vacuum flow to prevent any more water from
entering the tank. Turn off the vacuum, and empty the recovery tank.
NOTE
: If foam is present, or if the ball float is prevented from rising, the float will not be able to stop the air
flow, and the tank may over fill.
CAUTION!
To avoid vacuum motor damage, always make sure the float filter is clean and the ball can travel freely prior
to using the machine. And always use a defoamer when foaming occurs.
ELECTRIC CIRCUIT LOCATOR
This unique, patented system is operated by a solid state circuit. It will inform the operator when the two
cords are plugged into separate circuits by turning on the circuit locator light (see 1 on switch plate). This
helps to prevent tripping circuit breakers.
NOTE
: If the circuit locator light does not illuminate when the cords are plugged in, then both cords are on
the same circuit. Try other outlets with one of the cords until you get the locator light to come on.
NOTE
: If the heat switch (2 on switch plate) is turned on when both cords are on the same circuit, the breaker
will trip.