background image

Maintenance / Storage

Always disconnect the LP cylinder from the regulator
assembly and remove the LP cylinder from the heater
before putting the heater into storage. If for any reason the
heater is to be stored indoors, the heater MUST be
disconnected from the LP cylinder, and the cylinder stored
outdoors in a well- ventilated area, out of the reach of
children, and in accordance with the Standard for Storage
and Handling of Liquefied Gases, ANSI/NFPA 58 - latest
edition. The

plastic valve plug or valve cover supplied

with the LP cylinder must be reinstalled on the valve to
protect the fitting from damage.

NOTE: Repair of this heater should be done by a quali-
fied service person.

It is recommended that you save all of the packaging
materials that came with your heater, and re-package the
heater using these materials for safe storage.
Debris, dust and dirt inside of the heater body can affect
the performance of your heater.  This debris can impair the
heaters ability to draw air for ventilation and combustion.
Spiderwebs can also appear during periods of inactivity.

Be sure to inspect the heater before each use to look for
any such obstructions. Be sure to keep the air
passage-ways, burner and combustion areas clean. Wipe
with a damp cloth or use a vacuum cleaner to clean these
areas. It is suggested that you perform a thorough clean-
ing at least once every 30 days of operation.  You may
need to clean the heater more often if conditions are
naturally dirty.
Clean the Ceramic Plaques using compressed air below
30 PSI to prevent damage to plaques.

A yellow tip of the pilot flame indicates that the burner area
may be in need of cleaning.

WARNING! This heater is not intended for residential use.

Page 6

Pinnacle Products International, Inc.  Propane Cabinet Heater User’s Manual

Problem

Possible Cause

Solution

Burner does not light

1. Air in gas line

2. Gas pressure from cylinder too low

3. LP cylinder valve turned off

4. Obstruction in air passageway

5 Dirt in pilot orifice

6. Safety switch in cylinder valve

engaged

7. Tipover switch engaged

1. Keep depressing the gas control knob for at least

30 seconds to remove any air in line.

2. Check LP cylinder pressure. Tank may be empty

3. Open LP cylinder valve

4. Inspect and clean heater housing

5. Blow out, or otherwise clean the pilot orifice

6. Close LP cylinder valve. Wait one minute for

switch to click off. Reopen LP cylinder valve
slowly

7. Move heater to a level surface

No spark is created when
ignited

1. Incorrect igniter electrode position

2. Electrode damaged or broken

3. Loose or disconnected igniter wire

4. Broken igniter wire

1. Properly position electrode

2. Replace the electrode

3. Tighten or reconnect loose wire

4. Replace igniter wire

Heater stops running by
itself

1. Thermocouple damaged

2. Gas control valve damaged

3. Gas leak

4. Thermocouple not in contact with

pilot flame

5. Tip-over switch damaged, or loose

connection at tipswitch

6. Out of fuel

1. Replace thermocouple

2. Replace gas control valve

3. Check all connections for leaks using 50/50 solu-

tion of dishsoap and water. Repair any leaks
found

4. Clean inside of heater housing

5.Inspect tip-over switch and connections. Replace if

necessary

6. Replace LP cylinder

Never store an LP cylinder inside of a
building, or near any other gas or oil

burning appliances.

Always be sure that the heater has
been allowed to cool for at least 30

minutes before attempting to store, service, or
perform maintenance.

CAUTION

WARNING

Troubleshooting Guide

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A FUEL SOURCE

Propane

Cabinet Heaters

Содержание Heat-Stream HS-18-PCH

Страница 1: ...nternational Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Phone 215 891 8460 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com 500250410 10 Table of Contents Safety Information 2...

Страница 2: ...and approved for use as a con struction heater in accordance with ANSI Z83 7a CSA 2 14a 2007 Other standards determine the use of fuel gases and heat producing products for specific uses This infrare...

Страница 3: ...ezo Ignition Model HS 18 PCH uses a manual Piezo igniter to send a spark when you turn the Gas Valve Knob to PILOT IGN ignition The spark ignites the fuel at the pilot Tip Switch Shut Off System The h...

Страница 4: ...or two thirty two inch wide windows open 4 inches Connecting to Gas Supply IMPORTANT Always use a propane LP cylinder that has a connection device that is compatible with the hose and regulator assemb...

Страница 5: ...will heat the thermocouple After 30 seconds release the Valve Knob 6 If heater fails to light or does not stay lit repeat Steps 2 through 6 7 When burner stays lit turn Gas Valve Knob to desired setti...

Страница 6: ...or residential use Page 6 Pinnacle Products International Inc Propane Cabinet Heater User s Manual Problem Possible Cause Solution Burner does not light 1 Air in gas line 2 Gas pressure from cylinder...

Страница 7: ...010 0300 16 Tube M Assembly 50 010 0320 Item Number Part Description Part Number 17 Front Castor 50 011 0100 18 Nut 50 007 0200 19 Rear Castor 50 011 0200 20 Ceramic Holder 50 026 0100 21 Burner Assem...

Страница 8: ...ng condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims all warranties fo...

Страница 9: ...ntador produce mon xido de carbono que es un gas inodoro Encender el calentador en un espacio cerrado puede ocasionarle la muerte Nunca use el calentador en espacios cerrados como por ejemplo tiendas...

Страница 10: ...usarse en edificaciones en construcci n de acuerdo con las normas ANSI Z83 7a CSA 2 14a 2007 Otras normas regulan la aplicaci n de gases combustibles y materiales productores de calor a fines espec f...

Страница 11: ...y anulan su garant a Cuando no se use el calentador debe cerrarse el suministro de PL La cantidad de gas de PL que utiliza este calentador var a y est determinada por estos factores 1 La cantidad de g...

Страница 12: ...ejar abiertas 10 cm dos ventanas de 80 cm de ancho Conexi n del suministro de gas IMPORTANTE Siempre use cilindros de propano PL que tengan dispositivos de conexi n compatibles con el conjunto de mang...

Страница 13: ...lla de la v lvula 6 Si el calentador no se enciende o no permanece encendido repita los pasos 2 al 6 7 Cuando permanezca encendido el calentador gire la perilla de la v lvula hasta la temperatura de s...

Страница 14: ...ficio del quemador piloto 6 Accionado el interruptor de seguridad de la v lvula del cilindro 7 Accionado el interruptor de vuelco 1 Oprima la perilla de regulaci n del gas al menos 30 segun dos para v...

Страница 15: ...Rueda pivotante delantera 50 011 0100 18 Tuerca 50 007 0200 19 Rueda pivotante trasera 50 011 0200 20 Soporte cer mico 50 026 0100 21 Conjunto del quemador 50 005 0100 22 Chapa cer mica 50 005 0160 23...

Страница 16: ...or pagar Esta Garant a limitada sustituye toda otra garant a expresa Pinnacle Products International Inc desconoce toda garant a de productos comprados a vendedores que no sean minoristas o distribuid...

Страница 17: ...pas d odeur Le fait de faire br ler ce radiateur dans un espace clos peut causer la mort Ne jamais utiliser le radiateur dans des espaces clos comme une tente une camionnette de camping tout v hicule...

Страница 18: ...ur la reproduction AVERTISSEMENT ATTENTION AVERTISSEMENT Informations sur la s curit Ce radiateur est con u pour les sites de construction en conformit avec ANSI Z83 7a CSA 2 14a 2007 D autres normes...

Страница 19: ...rons Particularit s du produit Allumage pi zo Le mod le HS 18 PCH utilise un allumeur pi zo Manuel pour envoyer une tincelle lorsque l on tourne le bouton du robinet la position PILOT IGN allumage L t...

Страница 20: ...ux fen tres de 80 cm ouvertes sur 10 cm Raccordement une alimentation en gaz IMPORTANT Toujours utiliser une bouteille de GPL munie d un dispositif de raccordement compatible avec le tuyau et le r gul...

Страница 21: ...ra de chauffer le thermocouple Apr s 30 secondes rel cher le bou ton du robinet 6 Si le radiateur ne s allume pas ou ne reste pas allum r p ter les tapes 2 6 7 Lorsque le br leur est allum tourner le...

Страница 22: ...ans la canalisation d air 5 Salet dans l orifice du pilote 6 Interrupteur de s curit du robinet de la bouteille enclench 7 Interrupteur bascule enclench 1 Maintenir enfonc le bouton de commande de gaz...

Страница 23: ...oulette avant 50 011 0100 N de r f Description de la pi ce N de pi ce 18 crou 50 007 0200 19 Roulette arri re 50 011 0200 20 Support en c ramique 50 026 0100 21 Br leur 50 005 0100 22 Plaque de c rami...

Страница 24: ...ducts International Inc d termine que l article est dans un tat d utili sation normale ou n est pas d fectueux il sera retourn fret payable l arriv e Cette garantie limit e remplace toute autre garant...

Отзывы: