NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

© 2013, Pinnacle Products International, Inc. 

Kerosene Forced Air Heater User’s Manual 

®

12

Troubleshooting Guide

Locating Your Serial Number:

Your serial number can be found on a white label on the right side cover of your heater. It will begin 

with 2 digits, the letter “H” followed by 6 digits. For Example: 13H123456. Have your Serial Number 

ready before calling customer service at 800-641-6996.

Problem

Possible Cause

Solution

Heater Ignites, but main PCB shuts 

off after a short period of time. 

Lamp flickers and LED display 

shows “E1”.

1.  Incorrect pump pressure.

2. 

Dirty input, output or lint filter.

3. 

Dirty fuel filter.

4.  Nozzle is dirty.

5.  Photocell lens is dirty.

6.  Photocell not installed properly.

7.  Photocell is defective.

8.  Improper electrical connection 

between main PCB and photocell.

1.  Adjust pump pressure.

2. 

Clean / replace air or lint filter.

3. 

Clean / replace fuel filter.

4.  Clean / replace Nozzle.

5.  Clean / replace photocell.

6.  Adjust photocell position

7.  Replace photocell

8.  Check wiring connections  

(see wiring diagrams on page 11).

Heater will not operate or motor 

runs for a short time.

Lamp flickers and LED display 

shows “E1”.

1.  No kerosene in the fuel tank.

2.  Incorrect pump pressure.

3.  Corroded spark plug or incorrect 

plug gap.

4. 

Dirty fuel filter.

5.  Dirty nozzle.

6.  Moisture in fuel tank. 

7.  Improper electrical connection 

between transformer and circuit 

board.

8.  Ignitor wire not connected to spark 

plug.

9.  Defective ignitor. 

1.  Fill tank with fresh kerosene.

2.  Adjust pump pressure.

3.  Clean / replace spark plug. 

4. 

Clean / replace fuel filter. 

5.  Clean / replace nozzle.

6.  Rinse fuel tank with clean, fresh 

kerosene.

7.  Inspect all electrical connections. 

(See wiring diagrams on page 11.) 

8.  Re-attach ignitor wire to spark plug. 

9.  Replace ignitor.  

Fan does not operate when heater 

is plugged in and power switch is 

in the “ON” position. The lamp is 

flickering or and LED display shows 

“E1” or “E2”.

1.  Thermostat is set too low (does not 

apply to 45-KFA model).

2.  Broken electrical connection 

between main PCB and motor. 

1.  Rotate thermostat to a higher 

setting 

2.  Inspect all electrical connections 

(see wiring diagrams on page 11).

Lamp is flickering and LED display 

shows “E3”.

1.  Thermostat switch has failed.

1.  Replace thermostat switch (see 

Wiring diagrams on page 11).

Poor combustion and / or excess 

soot production. 

1. 

Dirty input, output or lint filter.

2. 

Dirty fuel filter.

3.  Poor quality of fuel.

4.  PSI is too high or too low. 

1. 

Clean / replace air or lint filter.

2. 

Clean / replace fuel filter.

3.  Flush fuel tank and refuel heater.

4.  Use proper pressure. 

Heater does not turn on and the 

lamp is not lit.

1.  Temperature limit sensor has 

overheated. 

2.  No electrical power.

3.  Fuse is blown.

4.  Improper electrical connection 

between temperature limit sensor 

and circuit board. 

1.  Push power switch to “OFF and 

allow heater to cool for 10 minutes. 

Restart heater. 

2.  Check power cords for proper 

connection and test the power 

supply.

3.  Check / replace the fuse.

4.  Inspect all electrical connections 

(see wiring diagrams on page 11).

Содержание HeatStream HS- 45-KFA

Страница 1: ...ersons who can follow and understand these instructions should operate or service this heater If you need heater info such as an operating manual labels etcetera contact Pinnacle Products Internationa...

Страница 2: ...to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production explosions burns as...

Страница 3: ...ell ventilated areas Provide at least a three square foot 2 800 sq cm opening of outside air for every 100 000 Btu Hr heater rating Refer to Ventilation on page 7 for further instructions ALWAYS use o...

Страница 4: ...2 7 2 8 Phase Single Single Single Single Single Specifications subject to change without notice Hot Air Outlet Upper Shell Lower Shell Fuel Tank Fan Guard Pressure Gauge Fuel Gauge Fuel Cap Side Cove...

Страница 5: ...les in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Insert screws 13 mm and tighten firmly Cord Wrap Assembly 1 Insert tabs into square slots in shell support and line up sc...

Страница 6: ...8 mm open end wrench 19 mm open end wrench Assembly Instructions Models HS 125T KFA HS 175T KFA HS 215T KFA What s In The Box 50 mm Screws 4 30 mm Screws 8 8 mm Nuts 12 Tires 2 Cord Wraps 2 Axle Nuts...

Страница 7: ...l 4 screws are secure 7 Attach rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the rear of the heater on either side See Figure 6 8 Tilt the heater up gently so it is resti...

Страница 8: ...HIS HEATER NOTE Kerosene should only be stored in a blue container that is clearly marked Kerosene Never store kerosene in a red container Red is associated with gasoline Ventilation Risk of indoor ai...

Страница 9: ...ob to desired temperature setting The thermostat set range is from 40 F to 110 F 3 Move power switch to On position The power indicator light and room temperature display will illuminate and heater wi...

Страница 10: ...WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe operating conditio...

Страница 11: ...osene Contaminated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models 45 70T KFA turn filter 90 clockwise To remove the filter from models 125T 175T 2...

Страница 12: ...r Pump Pressure HS 45 KFA 3 0 PSI HS 70T KFA 4 0 PSI HS 125T KFA 5 0 PSI HS 175T KFA 7 5 PSI HS 215T KFA 9 0 PSI Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating se...

Страница 13: ...rcuit board 8 Ignitor wire not connected to spark plug 9 Defective ignitor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace...

Страница 14: ...International Inc Kerosene Forced Air Heater User s Manual 13 17 14 16 11 15 12 40 43 47 34 4 19 17 3 5 35 8 7 1 2 9 28 29 27 32 21 22 23 31 26 30 29 18 56 48 50 51 39 38 6 46 45 44 36 42 10 41 20 33...

Страница 15: ...0100 70 054 0100 26 Lint Filter 70 054 0102 70 054 0102 70 054 0102 70 054 0102 70 054 0102 27 Output Filter 70 054 0100 70 054 0100 70 054 0100 70 054 0100 70 054 0100 28 Intake Filter 70 054 0101 7...

Страница 16: ...be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclai...

Отзывы: