background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

LIMITED WARRANTY

Pinnacle Climate Technologies, Inc.

 warrants this heater 

to the original retail purchaser only, to be free from defects 

in material and workmanship for a period of one (1) year 

from the date of initial purchase. This product must be 

properly installed, maintained and operated in accordance 

with the instructions provided.

Pinnacle Climate Technologies, Inc. 

requires reasonable 

proof of your date of purchase from an authorized retailer 

or distributor.  Therefore, you should keep your sales slip, 

invoice or cancelled check from the original purchase.  

This Limited Warranty shall be limited to the repair or 

replacement of parts, which prove defective under normal 

use and service within the warranty period, and which 

Pinnacle Climate Technologies , Inc.

 shall determine at 

its reasonable discretion. 

This warranty does not apply to products purchased for 

rental use. 

This Limited Warranty does not cover any failures or 

operating difficulties due to normal wear and tear, accident, 

abuse, misuse, alteration, misapplication, improper 

installation or improper maintenance and service by you 

or any third party.  Failure to perform normal and routine 

maintenance on the heater, shipping damage, damage 

related to insects, birds or animals of any kind, and damage 

due to weather conditions are also not covered.   

In addition, the Limited Warranty does not cover damage 

to the finish, such as scratches, dents, discoloration, rust or 

other weather damage, after purchase. 

All transportation costs for the return of damaged product 

or parts will be the responsibility of the purchaser. Upon 

receipt of damaged item, 

Pinnacle Climate Technologies, 

Inc. 

will examine the item and determine if defective. 

Pinnacle Climate Technologies, Inc. 

will repair or replace 

and return the item, freight pre-paid. 

If 

Pinnacle Climate Technologies, Inc. 

finds the item to 

be in normal operating condition, or not defective the item 

will be returned freight collect. This Limited Warranty is 

in lieu of all other express warranties. 

Pinnacle Climate 

Technologies, Inc.

 disclaims all warranties for products 

that are purchased from sellers other than authorized 

dealers or distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 

WARRANTY EXPIRES, 

Pinnacle Climate Technologies, 

Inc. 

DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES 

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

APPLICATION. FURTHER, 

Pinnacle Climate Technologies, 

Inc. 

SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER 

OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE 

INCIDENTAL, OR CONSEQUENTIAL DAMAGES. 

Pinnacle 

Climate Technologies, Inc. 

assumes no responsibility for 

any defects caused by third parties. This Limited Warranty 

gives the purchaser specific legal rights; a purchaser may 

have other rights depending upon where he or she lives. 

Some states do not allow the exclusion or limitation of 

special, incidental or consequential damages, or limitations 

on how long a warranty lasts, so the above exclusion and 

limitations may not apply to you.  

Pinnacle Climate Technologies, Inc. 

does not authorize 

any person or company to assume for it any other 

obligation or liability in connection with the sale, installation, 

use, removal, return or replacement of its equipment, and 

no such representations are binding on 

Pinnacle Climate 

Technologies, Inc.

Always be sure to specify the model number and serial 

number when making any claim with 

Pinnacle Climate 

Technologies, Inc. 

For your convenience, use the space 

provided below to list this information.

Model #:________________________________

Serial #:________________________________

Date of Purchase: ________________________

12

Locating Your Serial Number:

Your serial number can be found on a white label on the right side cover of your heater. It will be a 

series of 9 digits. For Example: 136985632. Have your Serial Number ready before calling customer 

service at 866-676-1989.

 

Serial Number Label

XX-X-XXX

XXX

 

Содержание Remington REM-135T-KFA-O

Страница 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Страница 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Страница 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Страница 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Страница 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Страница 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Страница 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Страница 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Страница 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Страница 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Страница 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Страница 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Страница 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Страница 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Отзывы: