Problem
Possible Cause(s)
Solution
Fan does not turn when
electricity is connected.
1. No electric power to heater.
2. Blades of fan in contact with
heater housing.
3. Fan blades bent.
4. Fan motor defective.
1. Check current at outlet. If voltage
is correct, inspect extension and
power cords for cuts, frays or
breaks
2. Check housing for damage. Be
sure there are no dents in the
housing obstructing the fan.
3. Straighten all fan blades.
4. Replace motor assembly.
Heater will not fire (ignite).
1. No spark at module.
2. Incorrect spark gap.
3. Corroded electrode.
1. Inspect module wire. Re-attach
or tighten if loose. Inspect spark
module and replace if necessary.
Inspect all other electrical
components.
2. Set plug gap to 0.16” (4 mm).
3. Replace spark plug
(multi-bracket assembly).
Heater stops running
by itself.
1. Temperature inside heater is too
high, causing thermal switch to
shut down operation.
2. Damaged control valve.
3. Dust or Debris accumulated
in heater.
1. If the heater input or output is
restricted, the inside temperature
can become too hot. Keep the
areas in front and behind heater
clear of obstructions.
2. Replace control valve.
3. Clean inside of heater.