background image

© 2018, Pinnacle Climate Technologies, Inc. 

Manuel de l’utilisateur de la chaufferette au kérosène

 

NE JAMAIS LAISSER UNE CHAUFFERETTE SANS 

SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST 

BRANCHÉE À UNE SOURCE DE COMBUSTIBLE.

15

1

2

4

3

5

6

7

8

9

10

11

12

13

14

15

16

17

18

24

20

22

21

30

23

26

19

34

27

29

42

31

31

32

25

28

VUE ÉCLATÉE

125-OFR-B

Содержание REMINGTON REM-125-OFR-B

Страница 1: ...QUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTERATION OR REPAIR This is an unvented portable heater that uses air Oxygen from within the area in which it is used Failure to provide...

Страница 2: ...ATER WHEN THE CHAMBER IS HOT WARNING WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as r...

Страница 3: ...The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction alte...

Страница 4: ...tion Gal Hr L Hr 0 63 2 38 0 85 3 22 Fuel Tank Capacity Gal L 4 15 14 14 53 Max Operating Hours 7 2 7 Volts AC Hz 120 V 60 Hz 120 V 60 Hz Amps 3 15 3 15 Heating Area ft 2 2000 4198 Specifications subj...

Страница 5: ...Attach the handle while still in the box for easier unpacking see Figures 1 and 2 Carry Handle 1 Black Screws 2 80 OFR B 1 Remove existing screws from shell ring on either side of heater see Figure 3...

Страница 6: ...ed see Figure 8 4 Attach Radiant Visors to the top and bottom rear of the Radiant Cone Assembly using extra screws included 5 Attach top safety guard using the two outer most extra screws on the top o...

Страница 7: ...ct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosen...

Страница 8: ...fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the power swi...

Страница 9: ...SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the terminals to 0 140 3 5 mm see Figure 12 FAN...

Страница 10: ...ozzle in clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a c...

Страница 11: ...te Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 11 125 OFR B WIRING DIAGRAMS AC 120V 60Hz AC 250V 3 15A ELECT...

Страница 12: ...lug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transformer w...

Страница 13: ...s Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 13 EXPLODED VIEW 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Страница 14: ...0650 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit...

Страница 15: ...erosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 15 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 4...

Страница 16: ...ump 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower M...

Страница 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Страница 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Страница 19: ...E INT RIEUR PERMIS SEULEMENT POUR LE CHAUFFAGE TEMPORAIRE DES STRUCTURES OU DES B TIMENTS BIEN VENTIL S EN COURS DE CONSTRUCTION DE MODIFICATION OU DE R PARATION Ceci est une chaufferette portative no...

Страница 20: ...NT NE PAS METTRE EN MARCHE LA CHAUFFERETTE LORSQUE LA CHAMBRE DE COMBUSTION EST CHAUDE AVERTISSEMENT RISQUE D INCENDIE DE BR LURE D INHALATION ET D EXPLOSION Garder les mat riaux combustibles tels que...

Страница 21: ...V TEMENTS OU DE TOUT MAT RIAU COMBUSTIBLE Les produits d crits dans ce manuel sont des chaufferettes feu direct et air puls aliment es au k ros ne Les chaufferettes air forc au k ros ne sont principal...

Страница 22: ...20 V 60 Hz Amp res 3 15 3 15 Surface chauff e m2 186 390 Sp cifications sujettes modification sans pr avis CARACT RISTIQUES JAUGE DE PRESSION DU CARBURANT DERRI RE LE CAPOT AMOVIBLE ENVELOPPE ANNEAU D...

Страница 23: ...haufferette est encore dans la bo te pour faciliter le d ballage voir les Figures 1 et 2 Figure 1 Figure 2 Poign e 1 Vis noires 2 80 OFR B 1 Retirer les vis existantes de l anneau de chaque c t de la...

Страница 24: ...es plaques de rayonnement sur la partie arri re sup rieure et inf rieure du c ne de rayonnement l aide des vis suppl mentaires incluses 5 Fixer la protection de s curit sup rieure l aide des deux vis...

Страница 25: ...soleil ou proximit d une source de chaleur NE JAMAIS utiliser du k ros ne entrepos la saison pr c dente pour la saison suivante Le k ros ne se d t riore avec le temps LE VIEUX K ROS NE NE BR LE PAS CO...

Страница 26: ...sible et le remplacer le cas ch ant V rifier galement la source d alimentation pour s assurer de la tension correcte 1 Compl ter les tapes 1 3 ci dessus 2 Placer l interrupteur la position de MARCHE L...

Страница 27: ...l cartement entre les lectrodes toutes les 600 heures de fonctionnement ou remplacer s il y a lieu Apr s l enl vement de la bougie nettoyer les bornes avec une brosse m tallique R gler l cartement des...

Страница 28: ...4a et 14b CELLULE PHOTO LECTRIQUE La cellule photo lectrique doit tre nettoy e au moins une fois par saison de chauffage ou plus fr quemment suivant les conditions Utiliser un coton tige tremp dans de...

Страница 29: ...INCIPAL MOTEUR DU VENTILATEUR MOTEUR DE REFROIDISSEMENT POMPE CCI DU PANNEAU VOYANT DE FONCTIONNEMENT VOYANT D ERREUR INTERRUPTEUR ANTI RENVERSEMENT LIMITEUR DE TEMP RATURE CELLULE PHOTO LECTRIQUE PRI...

Страница 30: ...e 3 Nettoyer remplacer le filtre carburant 4 Nettoyer remplacer la buse 5 Rincer le r servoir de carburant avec du k ros ne diesel neuf propre 6 V rifier toutes les connexions lectriques Voir les Sch...

Страница 31: ...ur de la chaufferette au k ros ne NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU ELLE BR LE OU QU ELLE EST BRANCH E UNE SOURCE DE COMBUSTIBLE 13 VUE CLAT E 25 23 24 9 21 22 20 19 26 10 7...

Страница 32: ...e 75 027 0650 9 Allumeur 75 025 0120 10 Carte de circuits imprim s principale 75 025 0400 11 Interrupteur anti basculement 75 051 0200 12 Moteur de refroidissement 75 047 0250 13 Ventilateur de refroi...

Страница 33: ...a chaufferette au k ros ne NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU ELLE BR LE OU QU ELLE EST BRANCH E UNE SOURCE DE COMBUSTIBLE 15 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 2...

Страница 34: ...rburant 72 027 0100 11 Carte de circuits imprim s principale et fusible 72 025 0450 12 Interrupteur anti basculement 75 051 0200 13 Cordon lectrique 72 032 0150 14 Interrupteur d alimentation 72 012 0...

Страница 35: ...acle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technnologies Inc d termine que l article est dans un tat normal d utilisation ou n est pas...

Страница 36: ...Industrial Blvd 101 Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2018 Pinnacle Climate Technologies In...

Отзывы: