![Pima OutView Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/pima/outview/outview_installation-manual_1557061005.webp)
Maintenance
5
5.
Connect the AC adapter wires to the Red (+) and Black (-) wires, on the terminal block. See
the next section for a diagram.
The positive wire of the AC adapter is marked with stripes
6.
Connect the wire from the trigger source to the Yellow wire of the OutView, on the terminal
block. See the next diagram.
Two-state triggers, like door contacts and beam detectors, cannot be used.
7.
Release the screw on the junction box, on the side of the adapter and the trigger wires, and
remove the plastic clip.
8.
Put the isolator, now with the wires inserted into it, back in its place.
9.
Replace the clip on the wires and fasten the screw.
10.
Close the lid and make sure it is fastened by all four clasps.
11.
Place the junction box in a weatherproof placement.
12.
Plug the AC adapter to an indoor outlet.
Connection diagram
If the AC-DC adapter is also used to power the triggering detector,
make sure it does not exceed its power output.
The OutView does not report a restore event.
Maintenance
If the protective camera lens becomes dirty, clean it only with a lint-free cloth.
Trigger source (N.C.)
OutView
AC-DC
Adapter
Junction box
Red
Black
Yellow
AC-DC Adapter
Trigger source
(up to 50 m long)
OutView
(+)
(-)