Maintenance 

 

5  

5.

 

Connect the AC adapter wires to the Red (+) and Black (-) wires, on the terminal block. See 

the next section for a diagram. 

 

The positive wire of the AC adapter is marked with stripes 

 

6.

 

Connect the wire from the trigger source to the Yellow wire of the OutView, on the terminal 
block. See the next diagram. 

 

Two-state triggers, like door contacts and beam detectors, cannot be used. 

7.

 

Release the screw on the junction box, on the side of the adapter and the trigger wires, and 

remove the plastic clip. 

8.

 

Put the isolator, now with the wires inserted into it, back in its place. 

9.

 

Replace the clip on the wires and fasten the screw. 

10.

 

Close the lid and make sure it is fastened by all four clasps. 

11.

 

Place the junction box in a weatherproof placement. 

12.

 

Plug the AC adapter to an indoor outlet.  

Connection diagram 

 

 

 

If the AC-DC adapter is also used to power the triggering detector, 
make sure it does not exceed its power output. 

 

The OutView does not report a restore event. 

Maintenance 

If the protective camera lens becomes dirty, clean it only with a lint-free cloth. 
 

 

 

Trigger source (N.C.)

OutView

AC-DC 

Adapter

Junction box

Red

Black

Yellow

AC-DC Adapter

Trigger source 

(up to 50 m long)

OutView

(+)

(-)

Содержание OutView

Страница 1: ...OutView Outdoor Wireless Camera Installation Guide...

Страница 2: ...Still Image Camera Operated by Momentary Trigger from N C Normally Close Devices Detectors Relays etc Up to 7 m Flash for Low Light Conditions Weather Resistant Sun Light Protection External AC adapt...

Страница 3: ...lash The AC adapter should be connected to an indoor AC outlet The distance between the camera and the trigger source detector cannot exceed 50 m Ensure that outdoor power cables such as extension cor...

Страница 4: ...lock and to power see the next section for details 7 Adjust the field of view of the camera 8 Tighten the bracket s tilt screws with the supplied Allen wrench How to connect the OutView The OutView is...

Страница 5: ...ic clip 8 Put the isolator now with the wires inserted into it back in its place 9 Replace the clip on the wires and fasten the screw 10 Close the lid and make sure it is fastened by all four clasps 1...

Страница 6: ...Up to 7 m RF Frequency 2 4 GHz ISM band Modulation Frequency Hopping Spread Spectrum FHSS Supervision 2 way Radio Link 20 sec interval Event Transmission Alarm Image Low Battery Supervision Range Up t...

Страница 7: ...y damage or loss whatsoever whether directly indirectly incidentally consequentially or otherwise caused by the malfunction of the Product due to products accessories or attachments of others includin...

Страница 8: ...to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are des...

Страница 9: ...uide and the information contained herein are proprietary to PIMA Electronic Systems Ltd Only PIMA Electronic Systems Ltd or its customers have the right to use the information No part of this guide m...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...Ltd 5 Hatzoref Street Holon 5885633 ISRAEL Tel 972 3 650 6414 Fax 972 3 550 0442 E mail support pima alarms com sales pima alarms com www pima alarms com Distributed and Supported by P N 4410383 4410...

Отзывы: